SECTION 3 SBE 80 / SBO 60 SBE 80 / SBO 60 Connectors - up to 80 Amps SBE and SBO connectors build on the capability of the two pole SB connectors by offering up to 8 auxiliary power / signal contacts along with an IEC 60950 touch safe housing. The center of the main connector features a connector holder for either: two PP15-45, two PPMX, or APPs innovative 1x4 auxiliary connector. Touch Safe Interface Minimizes potential contact with live circuits per IEC 60950 Up to 8 Last Mate / First Break Auxiliaries Enables intelligent power switching, CAN and interlock loop circuitry, as well as power up to 20 amps per pole Silver Plated Wire Contacts up to 4 (25 mm) Allows UL rated currents up to 80 amps per pole SBE 80 / SBO 60 ORDERING INFORMATION SBE 80 / SBO60 Housings Mated Length The smallest size of SBE , X, O style housing. SBE 80 and SBO 60 housings of the same 112.2 Voltage Color Code can be mated but is not recommended as it invalidates UL approvals for 4.42 SBO 60. SBO 60 housings do not meet EN1175-1 requirements for industrial trucks. Description ----- SBE 80 Part Numbers ----- ----- SBO 60 Part Numbers ----- Minimum Quantity .... 400 25 400 25 ...... Yellow SBE80YEL-BK SBE80YEL SBO60YEL-BK SBO60YEL Orange SBE80ORN-BK SBE80ORN SBO60ORN-BK SBO60ORN Side View Red SBE80RED-BK SBE80RED SBO60RED-BK SBO60RED Gray SBE80GRA-BK SBE80GRA N/A N/A 26.3 Top View 1.03 White N/A N/A SBO60WHT-BK SBO60WHT 58.9 46.0 2.32 1.81 69.6 2.74 SBE 80 / SBO 60 Silver Plated Primary Power Wire Contacts 5.1 Use two silver plated contacts per housing for the best electrical performance and 0.20 durability up to 10,000 mating cycles. See reducing bushings in accessory 14.6 0.58 section for smaller wire size 49.5 1.95 Dimensions Mating - A - - B - AWG mm Force - Loose Piece Part Numbers - inches mm inches mm Minimum Quantity ........... 1,000 100 ................................................... 4 25 Low 1339G4-BK 1339G4 * 0.28 7.11 0.35 9.0 6 16 High 1339G1-BK 1339G1 * 0.22 5.59 0.29 7.3 * Sold as pairs. 2 parts shipped for every 1 part ordered. 39.4 1.55 13.0 0.51 B 7.6 0.30 A 2018 Anderson Power Products, Inc. All rights reserved. APP, Anderson Power Products, A, SBE, SBO, SBX, Powerpole and the APP Logo are registered trademarks of Anderson Power Products, Inc. - 87 - All Data Subject To Change Without Notice www.andersonpower.com SBE 80 / SBO 60 CONNECTOR SPECIFICATIONS Mechanical Electrical Wire Size Range AWG mm Current Rating Amperes SBO60 SBE80 Power Contacts 6 to 4 16 to 25 Primary Power (6 AWG) 70 80 Auxiliary Contacts 24 to 10 0.25 to 5.3 Powerpole Auxiliary (12 AWG) 20 20 1x4 Auxiliary (12 AWG) 20 20 Max. Wire Insulation Diameter in. mm PPMX Auxiliary (20 AWG) 7 UL 5 CSA Power Contacts 0.440 11.200 Powerpole Auxiliary 0.175 4.450 Voltage Rating AC/DC UL 1977 EN1175-1 4 1x4 Auxiliary 0.140 3.600 Primary Power 600 150 4 Powerpole Auxiliary 600 150 Operating Temperature F C 1x4 Auxiliary 200 SBO and SBE Housings -4 to 221 -20 to 105 PPMX Auxiliary 300 Mating Cycles No Load by Plating Silver (Ag) Gold (Au) Dielectric Withstanding Voltage Primary Power Power Contacts 10,000 Volts AC 2,200 Powerpole Auxiliary 10,000 1x4 Auxiliary 10,000 Avg. Mated Contact Resistance Milliohms PPMX Auxiliary 5,000 1 1/4 of 6 AWG wire 0.200 Hot Plug Current Rating Amperes - 250 cycles at 120V DC Avg. Mating / Unmating Force Lbf. N Power 60A Main Connector Housing 16 70 Powerpole Auxiliary 30A Per Powerpole Connector 5 22 1x4 Auxiliary 5A Per Contact in 1x4 Auxiliary 0.7 3.0 Per PPMX Housing 4.50 20.00 Materials Housing Min. Contact / Spring Retention Force Lbf. N SBE / SBO & 1x4 Auxiliary Housing Polycarbonate / PBT blend Power Standard Housing 50 222 Powerpole Plastic Resin Polycarbonate Powerpole Housing 25 111 Contact Retention Spring Stainless Steel 1x4 Auxiliary Housing 10 44.5 PPMX Housing 12 53 Housing Flammability Rating UL94 V-0 NOTE 1: See IEC 60664-1 for working voltage. Glow Wire - SBE80 Only 960C (GWFI) / 800C (GWIT) NOTE 2: Amp ratings are stated per position and based on all positions being fully loaded. Power & Powerpole Contact Silver Plated Copper Alloy Based on: 105C rated or better cable of the largest size, Properly calibrated APP recommended tooling, and a 25C ambient temperature. UL rating not to exceed 1x4 Auxiliary Contacts the maximum operating temperature. CSA rating below a 30C temperature rise. Pin Copper alloy, Au over Ni Only SBO 60 has UL recognition. Socket BeCu, Au over Ni Limited by the thermal properties of the connector plastic housing. Socket Body Copper alloy, Sn bright over Ni Use APP recommended tooling only. Alternate tools may adversely affect the Retention Clip Stainless Steel performance of our connectors along with UL and CSA recognition. 4 Voltage capability of SBE housings is identical to SBO , but derated to meet PPMX Contacts Gold Plated Copper Alloy EN1175-1 requirements. Contact Termination Methods Crimp Hand Solder IEC INFORMATION Connector Creepage/Clearance Material Series Configurations per IEC 60950-1 Group Unmated 4.23 mm SBE80 IIIa Mated 7.9 mm NOTE 3: Refer to the Constructional Data form for additional Protection information on our website., www.andersonpower.com Touch Safety Main Connector Housing IEC 60950 Pass IEC 60529 IP20 - 88 - All Data Subject To Change Without Notice www.andersonpower.com SECTION 3 SBE 80 / SBO 60