AR207 Multi-channel data recorder nmeasurement and recording of temperature from thermoresistance sensors and thermocouples and other physical values (humidity, pressure, level, flow, speed, etc.) processed to a standard electrical signal (0/420mA, 010V, 060mV, 0850) or pulse signals (frequency, flow, counting, etc.) 4GB n16 analog measurement inputs (mA, V) or 8 universal inputs (thermoresistance, thermocouple and Memory analog) or 8 pulse inputs or 8 mixed inputs (4 universal and 4 pulse), not galvanically insulated npulse inputs used for flow measurement, frequency or pulses counter (totalizer ) with reset input, can be USB used also as a bistable (digital) inputs n4 alarm/regulation outputs with sound and visual operating status signaling and e-mail notifications, RJ45 programmable characteristics, and the possibility to assign any measurement channels that trip the alarm PROTECTION RATING Ethernet na color graphic display, LCD TFT, 320x240 points (QVGA) with a touch screen, brightness adjustment, and IP30 programmable background color for individual measurement channels FROM THE FRONT RS485 nrich standard equipment with serial interfaces: USB (cooperation with a computer and USB memories), RS485 and Ethernet (100base-T, TCP/IP protocols), MODBUS-RTU and MODBUS-TCP nsaving data in standard text files stored in the recorder s internal memory (4 GB) or in a USB memory (FAT HTTP system) with possible edition in spreadsheets in such software as Microsoft Excel and OpenOffice Calc www nweb server for cooperation with any web browser (Opera, IE, Firefox, etc.), the site contains information on active measurement channels, time, status of outputs, recording, etc., with the possibility to present E-mail charts using the Google Chart API service (permanent Internet access is required to present charts) Alarm nthe DDNS service, which enables easy access over the Internet a recorder connected to a network that has no fixed public IP address, through a friendly Internet address defined by the user the service is available MODBUS TCP, RTU only for registered users of popular DDNS services, such as DynDNS (www.dyndns.org), No-IP (www.no-ip.com), and DNS-O-Matic (www.dnsomatic.com) PROTECTION RATING DDNS na programmable language of the menu and the site saved on web server (Polish, English) IP65 nprogrammable F button for quick selection of one of the available functions: stop/start of recording, FROM THE FRONT copying or transfer of archives into USB memory, blocking of outputs, sound alarms or touch screen and keypad, device and internet services status nprogrammable types of inputs, ranges of indications, alphanumeric description of channels and measurement groups, options of recording, alarms, display, communication, access, and other Methods of data presentation configuration parameters naccess to configuration parameters protected with a user password or not protected with a password nparameter configuration methods: from the film keypad and a touch screen located on the front panel of the device via the USB, the RS485, or the Ethernet and the ARSOFT-CFG free software (Windows Vista/7/8/10) or a user s application, the MODBUS-RTU and MODBUS-TCP communication protocols from configuration files saved in the USB memory or on a computer disk navailable protection of measurement data from unauthorized copy or modification ngraphic and text methods of presentation of the measured values (bar graph, analog indicator, chart) ngrouping of measurement channels to be displayed, with automatic formatting of the screen ninternal real time clock with a battery backup power supply (up to 8 years of continuous operation) nan integrated 24 V DC power supply supplying the field transducers, flowmeters, etc. ncompensation of line resistance for resistance sensors in 2- or 3-wire connection ncompensation of thermocouple cold tip temperature (automatic or permanent) nenclosed free software enabling graphic or text presentation of recorded result (ARSOFT-WZ3) and configuration of parameters (ARSOFT-CFG) nrecording of data until the memory is full (at least 300 days of continuous operation with recording of 16 Web Server channels every 1 s) na broad selection of methods of initiation of recording (continuous, limited by date and time, repeated daily, over or under a permission threshold connected with any measurement channel) nUSB drivers for Windows XP/Vista/7/8/10 npossibility to distinguish archives from many recorders of the same time thanks to individual assignment of an identification number (ID) nclearly visible status of operation of recording, memory, USB port, alarms, file and disk operations, serial transmission (USB, RS485, Ethernet), etc. nhigh accuracy and immunity to interferences npossibility to latest firmware upgrade via USB memory How to order AR207 / o / o / o/ o / o / o / o Order examples: Protection rating Code AR207 / 8 / S1 / P / P/ P / P / IP30 IP30 (USB also from the front) IP30 supply 230 Vac, 8 universal inputs IP65 (USB only at connector side) IP65 4 relay outputs, protection rating from The number and type of inputs Code Output 1, 2, 3, 4 Code the front IP30 8 universal inputs 8 relay P AR207 / 8A8U / S2 / P / P/ P / P / IP65 16 current inputs 16A for SRR S supply 24 Vac/dc, 8 current inputs, 16 voltage inputs 16U 8 voltage inputs 8 current + 8 voltage inputs 8A8U Supply Code 4 relay outputs, protection rating from 8 pulse inputs 230 Vac 8P S1 the front IP65 (USB available only from 4 universal + 4 pulse inputs 4P4 24 Vac/dc S2 connector side) APAR - Commercial Office, 05-090 Raszyn, ul. Gaczyskiego 6 www.apar.pl Tel: +48 22 101-27-31, +48 22 853-48-56 E-mail: automatyka apar.pl+24 V GND +24 V GND R +24V +24V +24V +24V IN3 +24V IN2 IN GND IN1 GND IN GND GND GND GND +24 V +24 V GND GND GND GND R R IN3 IN3 GND GND +24V +24V IN2 IN2 IN IN IN IN IN1 IN1 GND GND GND GND +24 V +24 V GND GND IN IN GND GND R R GND GND IN3 IN3 +24V +24V IN IN IN2 IN2 IN IN GND GND IN1 IN1 IN IN GND GND polycarbonate +24 V +24 V GND GND GND GND R R IN3 IN3 +24V +24V GND GND IN2 IN2 IN IN IN IN + 5V GND GND IN1 IN1 GND GND - RS +24 V +24 V IN IN GND GND + RS GND GND GND GND R R RGND IN3 IN3 +24V +24V IN IN IN2 IN2 IN IN GND GND IN1 IN1 GND GND IN IN TECHNICAL DATA DIMENSIONS INSTALLATION DATA Number of measurement inputs 16 analog or 8 universal/pulse inputs, not galvanically isolated Fixing methods grips on the side of the enclosure Universal inputs (programmable, 16 types), measurement ranges (1) 96 96 79 mm Enclosure dimensions - Pt100 (RTD, 3- or 2-wire) -200 850 C - thermocouple R (TC, PtRh13-Pt) -40 1600 C Panel window 92 89 mm - Pt500 (RTD, 3- or 2-wire) -200 620 C - thermocouple T (TC, Cu-CuNi) -25 350 C self-extinguishing NORYL 94V-0, polycarbonate Material - Pt1000 (RTD, 3- or 2-wire) -200 620 C - thermocouple E (TC, NiCr-CuNi) -25 850 C 7 72 16 - Ni100 (RTD, 3- or 2-wire) -50 170 C - thermocouple N (TC, NiCrSi-NiSi) -35 1300 C - thermocouple J (TC, Fe-CuNi) -40 800 C - current (mA, Rwe = 100 ) 0/4 20 mA - thermocouple K (TC, NiCr-NiAl) -40 1200 C - voltage (V, Rwe = 150 k ) 0 10 V NORYL 88 - thermocouple S (TC, PtRh 10-Pt) -40 1600 C - voltage (mV, Rwe > 2 M ) 0 60 mV - thermocouple B (TC, PtRh30PtRh6) 300 1800 C - resistance (R, 3-wire or 2-wire) 0 850 Current analog input (mA, programmable, 2 types) 0/4 20 mA (Rwe = 100 ) (2) Voltage analog input (V, programmable, 2 types) 0/2 10 V (Rwe = 200 k) (2) Pulse input - supported sensors outputs open collector PNP and NPN, contact (reed) ELECTRICAL CONNECTIONS - frequency range 0.035Hz 10kHz (3) a) 8 universal inputs version, (RTD, TC, mA, V, mV, R), INPUT1 INPUT8 - minimum duration of low/high level 25us (3) 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 - range of indications (totalizer / counter capacity) 99999 units RTD (3-w) - waiting time for a pulse (for flow and frequency) 0.1s 30s mA INPUT 5 INPUT 6 INPUT 7 INPUT 8 - switch debounce time ( insensibility time for contacts) without or programmable range 0,05 50ms RTD (2-w) short 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Response time (10 90%) 1 5 s (programmable) Resistance of leads (RTD, R) Rd < 25 (for each line) TC, mV V Resistance input current (RTD, R) 650 A (Pt100, Ni100, 850), 150 A (Pt500, Pt1000), multiplexed INPUT 1 INPUT 2 INPUT 3 INPUT 4 Processing errors (at ambient temperature of 25 C): b) 16 analog inputs version, (mA lub V), IN1 IN16 - basic - for RTD, mA, V,mV, R 0.1% of the measurement range 1 digit 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 - for thermocouples 0.2% of the measurement range 1 digit - additional for thermocouples < 2 C (compensation of temperature of cold tips) mA - additional from ambient temperature < 0.005% of the input range /C IN9 IN10 IN11 IN12 +24V IN13 IN14 IN15 IN16 +24V or -9999 19999 (resolution of analog inputs), 0 99999 (pulse inputs) Range of indications (programmable) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 V Resolution / dot position programmable, 0 0,000, for thermometric inputs 0,1 C or 1 C Communication - USB - slave mode (device, drivers for the Windows XP/Vista/7/8/10 IN1 IN2 IN3 IN4 +24V IN5 IN6 IN7 IN8 +24V communication with exchangeable disk (mass memory) + virtual COM interfaces (A4 socket type, a computer) serial port (MODBUS-RTU protocol) (in IP30 version programmable mode of operation) USB also c) 8 pulse inputs version, INPUT1 INPUT8 - master mode (host) support of USB memory (pendrive) up to 4 GB accessible 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 from the front) - RS485 MODBUS-RTU protocol, SLAVE, speed 2.4115.2 kbit/s, sign format 8N1, galvanic separation - Ethernet 100base-T, RJ45, web server, MODBUS-TCP, e-mail client (SMTP), DDNS server INPUT 5 INPUT 6 INPUT 7 INPUT 8 client, TCP/IP protocols: DHCP (client, server), SMTP, NetBIOS, ICMP, UDP, TCP, 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 data transfer up to 135 kB/s (depending on the network) NPN Data recording interval programmable 1 s to 8 hours (4) Data storage memory (non-volatile, recording of approx. 27x10 6 measurements from 16 channels and 4 GB memory): INPUT 1 INPUT 2 INPUT 3 INPUT 4 PNP - internal 4GB, FAT32 file system, micro SDHC card, industrial, MLC - external USB memory (pendrive) FAT16, FAT32, maximum size 4 GB, pendrive, A4 type socket d) 4 universal and 4 pulse inputs version, INPUT1 INPUT8 REED SWITCH Real time clock (RTC) quartz, date, time, takes leap years into account, CR1220 lithium battery - INPUT1 INPUT4 according to point a), above - INPUT5 INPUT8 according to point c), above - relay 5A / 250Vac (for resistance loads), SPST Outputs REED SWITCH (4 separate) - SSR (optional) ansistor, type NPN OC, 24V, internal resistance 850 e) other connections ETHERNET USB Display LCD TFT, 320x240 points - QVGA, 3.5 , background brightness adjustment RJ45 max. 4GB RS485 10/100 Touch panel resistance, integrated with LCD display Usup base-T P1 P2 P3 P4 Power - 230Vac 85 260 Vac/ 7VA supply (Usup) 45 46 47 48 49 50 51 52 53 54 41 42 43 44 - 24Vac/dc (option) 20 50 Vac/ 7VA, 22 72 Vdc/ 7W Power supply of field transducers 24Vdc/200mA (100 mA in the case of the 24 VAC/DC supply) SSR1 SSR2 SSR3 SSR4 Rated operating conditions 0 50C, <100 %RH (no condensation) NOTE: In the IP30 version, the USB connection is also available on the front panel. Operating environment air and neutral gases, no dust DO NOT USE SIMULTANEOULYWITH THE BACK CONNECTION Protection rating IP65 or IP30 from the front, IP20 from the side of the connections Notes : (1) - applies only to the recorder version with universal inputs Weight ~420g (2) - applies only to the recorder version with analog inputs (current or voltage) Electromagnetic - immunity: according to the PN-EN 61000-6-2:2002(U) standard (3) - for simultaneously measured flow and flow balance from the same sensor: 50 s (5kHz) or 100 s (2,5kHz) (details in chapter 12.5. PULSE MEASUREMENT INPUTS CONFIGURATION) compatibility (EMC) - emissivity: according to the PN-EN 61000-6-4:2002(U) standard (4) - in the case of recording interval of 1 s, the recording may be uneven during the transfer of the archive over the Ethernet and also due to the excessive number of files, their size, and the type and brand Version 1.3.2 2016.01.22 of the USB (pendrive) memory used APAR - Commercial Office, 05-090 Raszyn, ul. Gaczyskiego 6 www.apar.pl Tel: +48 22 101-27-31, +48 22 853-48-56 E-mail: automatyka apar.pl + + + + + + + + +