13-Serie 600H-600NH-A 16-Serie 600H-600NH-A 30/10/14 15:20 Page88 600H and 600NH series Toggle switches - high amperage Distinctive features and specifications UG1410A Construction Terminal and contact support are manufactured from a single piece of metal. The contacts are resistance-welded to the terminal for increased mechanical strength. Rating These switches are suitable for motor loads and power applications up to A 15A 250VAC or 10A 400VAC Metal or insulated lever UL, CSA and NF-VDE (EN 61058-1) approved ELECTRICAL SPECIFICATIONS Max. current/voltage ratings : see tables below Peak current : 30A max. during 1/2 sine, 250VAC Initial contact resistance : 10 m max. Insulation resistance : 1.000 M min. at 500VDC Dielectric strength : 2.000 Vrms 50 Hz min. between terminals 2.500 Vrms 50 Hz min. between terminals and frame Electrical life : 10.000 cycles at full load APPROVED RATINGS - FOR INFORMATION- 600H - 600NH Max. current/voltage rating w. resistive load MODELS FUNCTIONS UL CSA NF-VDE Functions Ratings Electrical life UL 1054 CSA 22-2 EN 61058-1 15A 250VAC ON - OFF ON - OFF (1) 10A 24VDC 10.000 cycles 15A 1/2 HP ON - ON 15A 12VDC 125-250VAC 10(4)A Single and ON - ON (6) 400VAC double pole 15A 250VAC 6.000 cycles ON OFF ON 5A 24VDC 10.000 cycles Other 10A 1/2 HP T 85/55 (600H) (4-5-7-8-9) 125-250VAC 15A 125VAC ON - OFF (1) 15A 1/2 HP T 125/55 Other 12A 250VAC 10.000 cycles & ON - ON (6) 125-250VAC (600NH) 5A 24VDC Three pole Other 10A 1/2 HP (4-5-7-8-9) 125-250VAC MATERIALS GENERAL SPECIFICATIONS Case : polyester UL94-V0 Torque : 1,50 Nm (1.10 Ft.lb) max. applied to nut Actuator : Panel thickness : 4,5 mm (.177) max. between 2 nuts - 600H : brass, nickel plated Operating temperature : -20C to +55C - 600NH : black polyamide Bushing : brass, nickel plated Contacts : silver/nickel alloy The company reserves the right to change specifications without notice. A-88 www.apem.com APEM13-Serie 600H-600NH-A 16-Serie 600H-600NH-A 30/10/14 15:20 Page89 600H and 600NH series Toggle switches - high amperage Specifications AGENCY APPROVALS MOUNTING RECOMMENDATIONS Connection For quick-connect terminals, use 6,3 x 0,8 mm normalized female connectors. For screw terminals, use : EN 61058-1 EN 61058-1 2 2 either 1,5 mm or 2,5 mm rigid wires, Availability : see chart on previous page. or prepared stripped and tin plated flexible wires, or prepared flexible wires with crimped termination per A Marking : approved models are standard marked. EN 50027 (DIN 46228) Ground connector PANEL CUT-OUT Compulsory if the panel is not metallic or not connected to ground. Should also be used when front face nut is of 12.20 12.20 12.50 plastic material. (.48DIA) (.48DIA) (.492DIA) Order separately, see section I. 3.50 (.137DIA) 1.70 (.066) APEM www.apem.com A-89 5.10 (.20) 9.60 (.377)