A02 series Keylock & selector switches Distinctive features and specifications A028 AX1607US Panel Sealed to IP65 Single pole to four pole Custom engraving & overmould key Captive screw & push on tab terminals 12A 250VAC ELECTRICAL SPECIFICATIONS PANEL CUT OUT Current/Voltage Rating : 25mA 5VAC Min, 12A 250VAC, 16A 250VAC max 12A 12VDC max Initial Contact Resistance : 10m max at 1A 4VDC Insulation Resistance : 50M min Dielectric Strength : 2KV between open contacts, 4KV live to accessible Electrical Life : 50,000 cycles min Contact Gap : Double break 2 x 1,5mm (0.059) Insulation : Class 2 MECHANICAL SPECIFICATIONS Mechanical Life (operator) : Momentary, 1 million cycles, maintained 100,000 cycles Lamp : Midget grove T1 filament, neon or LED Terminals : M3 captive screw and push on tab terminal 30.00 +0.15/-0.0 AGENCY APPROVALS GENERAL SPECIFICATIONS Operating Temperature : -20C to +85C Sealing : Panel sealed to IP65, rear of panel IP40 MATERIALS Key : Nickel plated steel Key Barrel : Chrome plated alloy Optional Metal Bezel : Nickel plated brass Operator : PBT Nut : ABS Camtrack Momentary : PPE Camtrack Maintained : PPSU Switch Block 1 & 2 Pole : PBT Switch Block 3 & 4 Pole : PEI Contacts : Gold plated silver Dimensions : first dimensions are in mm while inches are shown in brackets. Refer to the following pages for further information. Mounting accessories : standard hardware 1 nut and 1 sealing washer. The company reserves the right to change specifications without notice. APEM www.apem.com 1A02 series Keylock & selector switches Panel cut-out 22mm (0.866) or 29.5 (1.161) x 21.5(0.846)mm Keylock Selector APEM www.apem.com 2