Solid State Timers and Controllers Solid State 4210 AC Flasher The Model 4210 is an all solid state flasher intended for use in AC circuits only. Capable of flashing a load circuit up to one ampere at a fifty percent duty cycle. Output switch is ON for as long as it is OFF. Flash rates from 1 flash per minute up to 300 flashes per minute are available in five operating voltage ranges. The model 4210 has internal transient protection devices to assure reliable operation even when driving inductive load circuits such as relays or solenoids. Mechanical & Wiring 1.70 Mtg. Holes .76 .156 Dia90 .20 4 Places 2.25 2.65 Alternate Wiring .250 Quick Connect .27 .36 Terminals Timing Diagram . How To Find The Flash Rate . Timing Period vs Timing Resistance RangeThe timing diagram shown below is for an application that Output Always Turns ON First With requires the load circuit to be ON for 750 milliseconds and OFF Application of Operating Voltage for 750 milliseconds. (Remember - the ON and OFF times will essentially be equal due to the 50% duty cycle specification ON Time = OFF Time inherent in the model 4210) ON The voltage across the load circuit would look something this: OFF ON Time = 0.75 Sec (750 milliseconds) Output OFF Time = 0.75 Sec (750 milliseconds) ON OFF Operating Voltage Flash Period = ON + OFF Time Flash Period = .750 + .750 = 1.5 Seconds Flash Rate in Flashes Per Minute (FPM) 50% 50% FPM = 60 / Flash Period ON OFF FPM = 60 / 1.5 = 40 Flashes Per Minute V I S I T O U R W E B S I T E A T : www.artisancontrols.com Notice: Artisan Controls Corporation assumes no responsibility for customers applications or product design. The information and data contained herein is the sole and exclusive property of Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written consent of Artisan Controls Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party misusing this property Tel: 973-598-9400 Fax: 973-598-9410 Toll Free: 800-457-4950 Artisan Controls Corporation, 111 Canfield Ave., Bldg B15-18, Randolph, NJ, 07869, USA AC OPERATING VOLTAGE LOAD AC OPERATING VOLTAGE LOADSolid State Timers and Controllers Specifications Operating Voltage: AC only (12, 24, 48, 115, 230) 50/60 Hz. 15%. Voltage Tolerances: Timing Mode: Flasher. Fixed Flash Rate: Factory fixed at any rate from 1 to 300 flashes-per-minute (FPM) Fixed Flash Duty Cycle: 50%. Flash Rate Duty Cycle Tolerance: 10% (2% nominal). 2%, 5%, 10%, and 20% available. Tolerances On Fixed Timing: Flash Rate Variation: Less than 4% of set point over full temperature and voltage range. Repeatability Of Flashing Period: 2% at stabilized operating voltage temperature. Recycle Time: Operating voltage must be removed for a minimum of 200 milliseconds to assure that timing and output circuits are reset. If it is not a requirement that the load circuit always be energized when operating voltage is reapplied, the operating voltage may be re-applied at any time. Output Rating: 10mA to 1A inductive with inrush current to 8A for 8 milliseconds. Output Switch Voltage Drop: 3 volts AC maximum when load circuit is energized. Output Switch Leakage Current: 3 mA maximum when load circuit is de-energized. Output switch protected by silicon transient suppressors responding to Transient Protection: -12 transients within 1 x 10 seconds to a peak pulse power dissipation of 1500 watts, with transient surge currents to 200 amperes for durations up to 1/120 second at 25 C. Maximum transient voltage protection is 6000 volts as delivered through a source resistance of 30 ohms with a maximum duration of 8.3ms. Dielectric: 1500V rms all terminals to case. Operating Temperature: -20C to +85C MTBF Rating: 50,000 hrs minimum. Construction: Encapsulated module with .25 quick connect wiring terminals. UL File E47858, Appliance Controls - Component ATNZ2, Auxilliary Devices - Agency Recognitions: Component NKCR2. February 21, 2006 Data Sheet Revision Date: Ordering Information Part Number - Operating Voltage - Flash Rate (FPM) Specify Fixed 12 Flash Rate 24 Required From 4210 - 48 1 to 300 Flashes 115 Per Minute (FPM) 230 Part Number Examples 4210-24-90FPM A model 4210 operating from 24V AC with a flash rate of 90 flashes-per-minute (FPM) The load circuit will be ON for 333mS and OFF for 33mS. 4210-115-60FPM A model 4210 operating from 115V AC with a flash rate of 60 flashes-per-minute (FPM) The load circuit will be ON for 500mS and OFF for 500 mS. V I S I T O U R W E B S I T E A T : www.artisancontrols.com Notice: Artisan Controls Corporation assumes no responsibility for customers applications or product design. The information and data contained herein is the sole and exclusive property of Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written consent of Artisan Controls Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party misusing this property Tel: 973-598-9400 Fax: 973-598-9410 Toll Free: 800-457-4950 Artisan Controls Corporation, 111 Canfield Ave., Bldg B15-18, Randolph, NJ, 07869, USA