2/17/2010 200WConstantCurrentLEDDriverLEDWC200series FEATURES Ultra High Efficiency (Up to 92%) Active Power Factor Correction (Up to 0.99) Waterproof (IP67) Lightning Protection Over Voltage, Over Temp. & Short Circuit Protection Comply with UL8750 & EN61347 Safety Regulations Very High MTBF & Life Time SPECIFICATION Model LEDWC-200S045ST LEDWC-200S070ST LEDWC-200S105ST LEDWC-200S140ST LEDWC-200S175ST LEDWC-200S210ST LEDWC-200S245ST LEDWC-200S280ST 450mA 700mA 1050mA 1400mA 1750 mA 2100 mA 2450 mA 2800 mA Rated Current (1) Current Range (Min - Max) mA 427 - 473 665 - 735 997 - 1103 1330 - 1470 1662 -1838 1995 - 2205 2327 - 2573 2660 - 2940 200W 200W 200W 200W 200W 200W 200W 200W Rated Power 3% V Pk -Pk Ripple & Noise (max.) (2) 445 Vdc 285 Vdc 190 Vdc 142 Vdc 114 Vdc 95 Vdc 81 Vdc 71 Vdc Max. Voltage 267V - 445V 171V - 285V 114V - 190V 85V - 142V 68V - 114V 57V - 85V 48V - 81V 42V - 71V Voltage Range (Min - Max) 1% Line Regulation 3% Load Regulation 1.0 S Setup, Rise Time 90V ~ 305VAC Voltage Range 47Hz / 63Hz Frequency Range 0.99 100VAC and 0.96 220 VAC Power Factor Correction 92% 92% 92% 92% 91% 91% 91% 91% Efficiency (Typ.) at 230Vac 65A 230VAC Input and 25C Inrush Current 2.4 A / 100VAC 1.2A / 220VAC AC Current (Typ.) Protection type : Hiccup mode, recovers automatically after fault condition is removed Short Circuit Protection 110C Latch mode. The powpper supplpyy shall return to normal operp ation onlyy after the powp er is turn-on agaig n. OOverver TTemperatureemperature PProtectionrotection 601 V 385 V 257 V 192V 154V 128V 109V 96V Over Voltage (Typ.) Protection type : latch-off mode, Power supply must turn off and on again - 35C ~ 70C Operational Temperature Range Storage - 40 ~ +85C Operational 10 ~ 100% RH Humidity Storage 5 ~100% R.H UL8750 compliance to UL1012 UL935, CSA-C22.2 (No. 0, No 107.1, No. 250.0) Safety Standards I/P - O/P: 3KVAC (4242 DC) I/P - FG: 1.5KVAC (2121 DC) O/P-FG: 0.5KVAC (707 DC), 1 minute Withstand Voltage EN55015 with 6db margin EMI Conduction & Radiation EN61000-3-2 , EN61000-3-3 Harmonic Current EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN 61547 EMS Immunity MTBF (3) 310K HRS Compliance: MIL-HDBK-217F 25C ambient temp. 78,000 hours 45C ambient temp. Life Time (3) 238*79.5*46.0 (mm) -9.37*3.13*1.81 (inch) Dimension (L*W*H) 1500 g Weight Autec Power Systems www.autec.com 667 E Cochran St, Simi Valley, CA93065 Tel: (805)522-0888 Fax: (805)522-8777 Others Safety & EMC Environmental Protecttiions Input Output2/17/2010 Model LEDWC-200S315ST LEDWC-200S350ST LEDWC-200S420ST LEDWC-200S490ST LEDWC-200S560ST LEDWC-200S630ST LEDWC-200S833ST 3150 mA 3500 mA 4200 mA 4900 mA 5600 mA 6300 mA 8830 mA Rated Current (1) Current Range (Min - Max) mA 2992 - 3308 3325 - 3675 3990 - 4410 4655 - 5145 5320 - 5880 5985 - 6615 7915 - 8745 200W 200W 200W 200W 200W 200W 200W Rated Power 3% V Pk -Pk Ripple & Noise (max.) (2) 63 Vdc 57 Vdc 47 Vdc 40 Vdc 35 Vdc 32 Vdc 24 Vdc Max. Voltage 38V - 63V 34V - 57V 28V - 47V 24V - 40V 21V - 35V 19V - 32V 14V - 24V Voltage Range (Min - Max) 1% Line Regulation 3% Load Regulation 1.0 S Setup, Rise Time 90V ~ 305VAC Voltage Range 47Hz / 63Hz Frequency Range 0.99 100VAC and 0.96 220 VAC Power Factor Correction 91% 91% 91% 91% 91% 91% 90% Efficiency (Typ.) at 230Vac 65A 230VAC Input and 25C Inrush Current 2.4 A / 100VAC 1.2A / 220VAC AC Current (Typ.) Protection type : Hiccup mode, recovers automatically after fault condition is removed Short Circuit Protection 110C Latch mode. The power supply shall return to normal operation only after the power is turn-on again. Over Temperature Protection 85V 77V 63V 54V 47V 43V 32V Over Voltage (Typ.) Protection type : latch-off mode, Power supply must turn off and on again - 35C ~ 70C Operational Temperature Range Storage - 40 ~ +85C Operational 10 ~ 100% RH Humidity Storage 5 ~100% R.H UL8750 compliance to UL1012 UL935, CSA-C22.2 (No. 0, No 107.1, No. 250.0) Safety Standards I/P - O/P: 3KVAC (4242 DC) I/P - FG: 1.5KVAC (2121 DC) O/P-FG: 0.5KVAC (707 DC), 1 minute Withstand Voltage EN55015EN55015 wwithith 6db6db margmarginin EMI Conduction & Radiation EN61000-3-2 , EN61000-3-3 Harmonic Current EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN 61547 EMS Immunity MTBF (3) 310K HRS Compliance: MIL-HDBK-217F 25C ambient temp. 78,000 hours 45C ambient temp. Life Time (3) 238*79.5*46.0 (mm) -9.37*3.13*1.81 (inch) Dimension (L*W*H) 1500 g Weight Autec Power SystemsAutec Power Systems www.autec.comwww.autec.com 667 E Cochran St, Simi Valley, CA93065 667 E Cochran St, Simi Valley, CA93065 Tel: (805)522-0888Tel: (805)522-0888 Fax: (805)522-8777Fax: (805)522-8777 Others Safety & EMCC Environmental Protections Input Output