10 January 2014 Page 1 FEATURES LEDWCD26 Series 26W Constant Current LED Driver With Dimming High Efficiency (Up to 86%) 0-10V Dimming Control Active Power Factor Correction (Typical 0.95) High Temperature Operation Waterproof (IP66) RoHS Compliant Over Load & Short Circuit Protection Approved to UL8750 & EN61347 Safety Standards SPECIFICATION LEDWCD LEDWCD LEDWCD LEDWCD LEDWCD LEDWCD Model 026S035PS 026S045PS 026S070PS 026S105PS 026S140PS 026S175PS 350mA 450mA 700mA 1050mA 1400mA 1750mA Rated Current 26W 26W 26W 26W 26W 26W Rated Power Ripple & Noise +/-5 %Io (max.) Voltage Range 38~75 29~58 19~37 13~25 10~19 8 ~15 Line Regulation 1% Load Regulation 3% Output Overshoot / 10%Io Undershoot Turn On Delay 0.6S 110Vac, 0.3 220Vac Typ. No load output 85 59 42 32 26 22 Rated Voltage 100-277 Vac Frequency Range 47Hz / 63Hz Efficiency (Typ.) at 86% 85% 85% 84% 82% 81% 220Vac Inrush Current 60A (At 230Vac input 25 Cold Start. Duration=100 s) 0.4 A / 100 VAC 0.2 A / 220 VAC AC Current (Typ.) THD <15% Max. with a min. 50% load No damage shall occur when operating in a short circuit condition. Short Circuit The power supply shall auto recover when the fault condition is removed Over Load The power supply shall auto recover when the fault condition is removed Operational -20C ~ 70C (see derating curve) Temperature Range Storage - 40 ~ +85C Operational 10% ~ 100% RH Humidity Storage 5% ~100% R.H Safety Standards UL8750, UL935, UL1012, UL1310 Class 2, CSA-C22.2 No. 107.1, CSA C22.2 NO. 223-M91 Class 2 Conducted & EN55015 Class B Radiated EMI Harmonic Current EN 61000-3-2 EN 61000-3-3 , EN 61000-4-2 , EN 61000-4-3 , EN 61000-4-4 , EN 61000-4-5 , EN 61000-4-6 , EN 61000-4-8, EN 61000-4-11, EMS Immunity EN 61547 MTBF 200,000 hours ( Measured at 110Vac input, 80%Load and 25C ambient temperature (MIL-HDBK-217F) ) Dimensions (L*W*H) 78 80 27 (mm) - 3.07 3.15 1.06 (inch) 200 g Weight Autec Power Systems Tel: (805)522-0888 www.autec.com 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 Others Safety & EMC Environmental Protections Input Output 10 January 2014 Page 2 Mechanical Specifications Temperature Derating Life Time Curve Autec Power Systems Tel: (805)522-0888 www.autec.com 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777