4/16/2010 120WConstantCurrentLEDDriverLEDWC120series FEATURES Ultra High Efficiency (Up to 91%) Active Power Factor Correction (Up to 0.99) Waterproof (IP67) Dimming Function Lightning Protection Over Voltage, Over Temp. & Short Circuit Protection Comply with UL8750 & EN61347 Safety Regulations Very High MTBF & Life Time SPECIFICATION Model LEDWC( )120S035ST LEDWC( )120S045ST LEDWC( )120S070ST LEDWC( )120S105ST LEDWC( )120S140ST LEDWC( )120S175ST LEDWC( )120S210ST 350mA 450mA 700mA 1050mA 1400mA 1750 mA 2100 mA Rated Current (1) Current Range (Min - Max) mA 332 - 368 427 - 473 665 - 735 997 - 1102 1330 - 1470 1662 -1837 1995 - 2205 120W 120W 120W 120W 120W 120W 120W Rated Power 3% V Pk -Pk Ripple & Noise (max.) (2) 343 Vdc 266 Vdc 171 Vdc 114 Vdc 86 Vdc 68 Vdc 57 Vdc Max. Voltage 206V - 343V 160V - 266V 103V - 171V 68V - 114V 52V - 86V 41V - 68V 34V - 57V Voltage Range (Min - Max) 1% Line Regulation 3% Load Regulation 0.6 S Setup, Rise Time 90V ~ 305VAC Voltage Range 47Hz / 63Hz Frequency Range 0.99 100VAC and 0.96 220 VAC Power Factor Correction 91% 91% 91% 90.5% 90.5% 90.5% 90.5% Efficiency (Typ.) at 230Vac 65A 230VAC Input and 25C Inrush Current 1 mA max. at 277 Vac 50Hz input Leakage Current 1.5 A / 100VAC 0.75A / 220VAC AC Current ((yTyp.p )) Protection type : Hiccup mode, recovers automatically after fault condition is removed Short Circuit Protection 110C Latch mode. The power supply shall return to normal operation only after the power is turn-on again. Over Temperature Protection 446V 346V 222V 148V 112V 88V 74V Over Voltage (Typ.) Protection type : latch-off mode, Power supply must turn off and on again Operational - 35C ~ 65C Temperature Range Storage - 40 ~ +85C Operational 10 ~ 100% RH Humidity Storage 5 ~100% R.H UL8750 compliance to UL1310 Class 2 UL1012 UL935, CSA-C22.2 (No. 0, No 107.1, No. 250.0) Safety Standards I/P - O/P: 3KVAC (4242 DC) I/P - FG: 1.5KVAC (2121 DC) O/P-FG: 0.5KVAC (707 DC), 1 minute Withstand Voltage EN55015 with 6db margin EMI Conduction & Radiation EN61000-3-2 , EN61000-3-3 Harmonic Current EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN 61547 EMS Immunity 320K HRS Compliance: MIL-HDBK-217F 25C ambient temp. MTBF (3) 80,000 hours 45C ambient temp. Life Time (3) 194*67.5*37.0 (mm) -7.64*2.66*1.46 (inch) Dimension (L*W*H) 1000 g Weight Autec Power Systems www.autec.com 667 E Cochran St, Simi Valley, CA93065 Tel: (805)522-0888 Fax: (805)522-8777 Others Safety & EMC Environmental Protections Input Output4/16/2010 Model LEDWC( )120S245ST LEDWC( )120S280ST LEDWC( )120S315ST LEDWC( )120S350ST LEDWC( )120S420ST LEDWC( )120S490ST 2450mA 2800mA 3150mA 3500mA 4200mA 4900mA Rated Current (1) Current Range (Min - Max) mA 2327 - 2572 2660 - 2940 2992 - 3307 3325 - 3675 3990 - 4410 4655 - 5145 120W 120W 120W 120W 120W 120W Rated Power 3% V Pk -Pk Ripple & Noise (max.) (2) 49 Vdc 43 Vdc 38 Vdc 34 Vdc 28 Vdc 24 Vdc Max. Voltage 29V - 49V 26V - 43V 23V - 38V 20V - 34V 17V - 28V 14V - 24V Voltage Range (Min - Max) 1% Line Regulation 3% Load Regulation 3 S Setup, Rise Time 10% When Power On or Off Output Overshoot / Undershoot 90V ~ 305VAC Voltage Range 47Hz / 63Hz Frequency Range 0.99 100VAC and 0.96 220 VAC Power Factor Correction 90.5% 90.5% 90.5% 90% 90% 89% Efficiency (Typ.) at 230Vac 65A 230VAC Input and 25C Inrush Current 1 mA max. at 277 Vac 50Hz input Leakage Current 1.5 A / 100VAC 0.75A / 220VAC AC Current (Typ.) Protection type : Hiccup mode, recovers automatically after fault condition is removed Short Circuit Protection 110C Latch mode. The power supply shall return to normal operation only after the power is turn-on again. Over Temperature Protection 64V 56V 49V 44V 36V 31V Over Voltage (Typ.) Protection type : latch-off mode, Power supply must turn off and on again Operational - 35C ~ 65C Temperature Range Storage - 40 ~ +85C Operationalp 10 ~ 100% RH Humidity Storage 5 ~100% R.H UL8750 compliance to UL1310 Class 2 UL1012 UL935, CSA-C22.2 (No. 0, No 107.1, No. 250.0) Safety Standards I/P - O/P: 3KVAC (4242 DC) I/P - FG: 1.5KVAC (2121 DC) O/P-FG: 0.5KVAC (707 DC), 1 minute Withstand Voltage EN55015 with 6db margin EMI Conduction & Radiation EN61000-3-2 , EN61000-3-3 Harmonic Current EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN 61547 EMS Immunity MTBF (3) 320K HRS Compliance: MIL-HDBK-217F 25C ambient temp. 80,000 hours 45C ambient temp. Life Time (4+B148) 194*67.5*37.0 (mm) -7.64*2.66*1.46 (inch) Dimension (L*W*H) 1000 g Weight Autec Power SystemsAutec Power Systems www.autec.comwww.autec.com 667 E Cochran St, Simi Valley, CA93065 667 E Cochran St, Simi Valley, CA93065 Tel: (805)522-0888Tel: (805)522-0888 Fax: (805)522-8777Fax: (805)522-8777 Others Safety & EMC Envvironmental Protections Input Output