100WConstantVoltageLEDDriverLEDU(W)V100series FEATURES Ultra High Efficiency (Up to 93%) Active Power Factor Correction Waterproof (IP67) Lightining Protection Over Voltage, Over Temp. , Short Circuit & Over current Protection Comply UL8750 & EN61347 Safety Regulations Very High MTBF & Life Time SPECIFICATION LEDU(W)V- LEDU(W)V- LEDU(W)V- LEDU(W)V- LEDU(W)V- LEDU(W)V- LEDU(W)V- LEDU(W)V- Model 100S012ST 100S024ST 100S036ST 100S042ST 100S048ST 100S054ST 100S081ST 100S105ST Voltage 12 Vdc 24 Vdc 36 Vdc 42 Vdc 48 Vdc 54 Vdc 81 Vdc 105 Vdc Max. Current 8.33 A 4.05 A 2.75 A 2.35 A 1.95 A 1.75 A 1.23 A 0.95 A Rated Power 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 5% Voltage Tolerance 1.5% Vo Ripple & Noise (max.) (2) 0 - 8.33 A 0 - 4.05 A 0 - 2.75A 0 - 2.35 A 0 - 1.95 A 0 - 1.75 A 0 - 1.23 A 0 - 0.95 A Current Range (Min - Max) 1% Line Regulation g 2% Load Regulation Setup, Rise Time 0.6S 110 VAC or 0.3S 220 VAC Output Overshoot / Undershoot 10% When Power On or Off Voltage Range U (Universal Input) = 90V ~ 264VAC Or W (Wide Range Input) = 90V ~305VAC 47Hz / 63Hz Frequency Range 0.99 110 VAC and 0.96 at 220 VAC Power Factor Correction Efficiency (Typ.) at 230Vac 91% 93% 93% 93% 92% 92% 93% 93% 65A 230VAC Input and 25C Inrush Current 1.2A / 100VAC 0.6A / 220VAC AC Current (Typ.) Protection type : Hiccup mode, recovers automatically after fault condition is removed Short Circuit Protection 110C max. temp. of components inside the case Over Temperature Protection 135% Io (Typ.) Protection type : Hiccup mode, recovers automatically after fault condition is removed Over Current Protection 15 V 30 V 47 V 52 V 59 V 68 V 95 V 125 V Over Voltage (Typ.) Protection type : latch-off mode, Power supply must turn off and on again Operational -35C ~ 70C Temperature Range Storage - 40 ~ +85C Operational 10 ~ 100% RH Humidity Storage 5 ~100% R.H Safety Standards UL8750 compliance to UL1310 Class 2 UL1012 UL935, CSA-C22.2 (No. 0, No 107.1, No. 250.0) No load Power Dissipation 1.5W Withstand Voltage I/P - O/P: 3KVAC (4242 DC) I/P - FG: 1.5KVAC (2121 DC) O/P-FG: 0.5KVAC (707 DC), 1 minute I/P - O/P, I/P - FG, O/P - FG: 100M Ohms / 500VDC Isolation Resistance EN55015 with 6db margin EMI Conduction & Radiation EN 61347-1, EN61347-2-13 CE EN61000-3-2 , EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EMS Immunity EN61000-4-5 EN61000-4-6, EN61000-4-8, EN61000-4-11, EN 61547 439K HRS Compliance: MIL-HDBK-217F 25C ambient temp. MTBF (3) 96,000 hours 45C ambient temp. Life Time (3) 184*67.5*37 (mm) - 7.24*2.66*1.46 (inch) Dimension (L*W*H) 950 g - 2.09Lbs Weight Autec Power Systems www.autec.com 667 E Cochran St, Simi Valley, CA93065 Tel: (805)522-0888 Fax: (805)522-8777 Others Safety & EMC Environmental Protections Input OutputMechanical Specification BLACK (ACL) WHITE (ACN) RED (V+) AC INPUT (3*AWG 18) DC OUTPUT (2*AWG 18) GREEN (GND) BLACK (V-) Unspecified tolerance: 0.2 PIN ASSIGNMENT SHIPPING SPECIFICATIONS AC DC CONNECTION Series UNITS PER CARTON CARTON WEIGHT Input Output LEDU(W)V-100 20.0 24Kg 52.91Lbs PIN 1 LINE (Black) +V (Red) INDIVIDUAL BOX DIEMENSION WIDTH LENGGTH HEIGGHT PIPINN 22 NEUNEUTTRARALL (W(Whhiteite)) -VV( (BBllackack)) Series inch 7.09 2.68 1.46 PIN 3 GROUND (Green) LEDU(W)V-100 180.0 68.0 37.0 mm Connector Flying lead (stripped and tinned) LEDU(W)V- LEDU(W)V- LEDU(W)V- LEDU(W)V- LEDU(W)V- LEDU(W)V- LEDU(W)V- LEDU(W)V- Model 120S012ST 120S024ST 120S036ST 120S042ST 120S048ST 120S054ST 120S081ST 120S105ST Efficiency Full Load and 115VAC (min) 88% 90% 89% 90% 89% 90% 90% 90% Efficiency Full Load and 115VAC (typ) 89% 91% 90% 91% 90% 91% 91% 91% Efficiency Full Load and 230VAC (min) 89% 92% 92% 92% 91% 91% 92% 92% Efficiency Full Load and 230VAC (typ) 91% 93% 93% 93% 92% 92% 93% 93% Derating Curve Derating Curve Derating Curve 100 100 80 80 60 60 40 40 20 20 0 0 -35 -20 -5 10 25 40 55 70 90 120 150 180 210 240 270 Input Voltage(V) Ambient Temperature(C) NOTES: 1. Measured at full load, 220VAC input and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth oscilloscope and the output paralleled a 0.1uf ceramic capacitor & 10 uf electrolytic capacitor. 3. For 54V output model, measured at 110VAC input, 80%load and 25 of ambient temperature. 4. For 54V output model, measured at 220VAC input, 80%load and 45 of ambient temperature. 5. All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25 of ambient temperature. 6. Specifications are subject to change without notice. AUTEC cannot be held liable for errors or omissions or the consequences thereof. 7. A suffix -XXXX may be added to denote variation or modifications to the base product, were X can be any alphanumeric character or blank Autec Power SystemsAutec Power Systems www.autec.comwww.autec.com 667 E Cochran St, Simi Valley, CA93065 667 E Cochran St, Simi Valley, CA93065 Tel: (805)522-0888Tel: (805)522-0888 Fax: (805)522-8777Fax: (805)522-8777 Load(%) Load(%)