24 December 2014 Page 1 FEATURES 120W Constant Voltage LED Driver LSWV-120 Series Wide AC Input 90~305VAC High Efficiency & High Power Factor Meets DLC & Energy Star p Operation from -35C-70C Full Load Certified to UL/cUL 8750, EN61347 & CE Short Circuit, Over Temperature & Over Voltage Protection IP67 RoHS Compliant SPECIFICATIONS Output Output PF (2) Ripple & Efficiency Model Current Range (5) Voltage (5) Noise (3) 220VAC (4) 110VAC 277VAC LSWV-120S024ST 0-5A 24 0.99 0.9 0.7V 88.0% 0-3.3A 36 0.99 0.9 1V 89.0% LSWV-120S036ST 0-2.5 48 0.99 0.9 1.6V 90.0% LSWV-120S048ST 1% Line Regulation 3% Load Regulation 0.8~1.2s Turn-on Delay Time 90~305VAC Voltage Range 47Hz~63Hz Frequency Range 65A cold start, Vin=230V Inrush Current 1.6 A / 110 VAC 0.7 A/ 220 VAC AC Current 0.75 mA Vin=277, 50Hz Leakage <20% 277 & 70% load THD Protection type: Hiccup mode, recovers automatically after fault condition is removed Short Circuit 110C Internal temperature. Auto recovers after power supply cools. Over Temperature 130% of max voltage. Latch mode. The power supply shall return to normal operation only after recycling AC. Over Voltage Operational -35C~70C Temperature Range Storage -40C~85C 10%~100%RH Operational Humidity Storage 5%~100% RH UL8750, UL935, UL1012, CSA-C22.2, NO. 107.1 EN61347-1, EN61347-2-13 Safety Standards EMI Conduction & EN55015 Radiation EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EMS Immunity EN61000-4-11, EN61547 275,000 hours MTBF 82,000 hours Life Time (L*W*H) 7.40*3.07*1.46 inches 188.5*78*37 mm Dimensions 900g Weight Autec Power Systems Tel: (805)522-0888 www.autec.com 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 Safety & Others Environment Protection Input Output EMC 24 December 2014 Page 2 Note: 1. All specifications are typical at 25C unless otherwise stated. 2. values are measured at 70% load, after the unit is thermally stabilized. 3. The Ripple & Noise values are measured by 20MHz bandwidth oscilloscope and the output paralleled a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor. 4. Typical at full load 5. +/- 5% Mechanical Specifications Derating Curves Autec Power Systems Tel: (805)522-0888 www.autec.com 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777