Data Sheet True RMS AC + DC Tool Kit DMM Model 2712 10 A range: (2.0% rdg + 10 dgts) RUE RMS Input Protection 0.5 A/500 V & 10 A/500 V fast blow ceramic fuses 10A Input 10 A for 60 sec max. followed by a 10 minute cooling period Voltage Burden 40 mA, 10 A ranges: 0.2V 400 mA range: 1 V AC Current (True RMS) (50 Hz-1 kHz) Ranges 40 mA, 400 mA, 10 A T Resolution 1 uA, 10 uA, 10 mA Accuracy 40 mA to 400 mA ranges: (2.0% rdg + 30 dgts) 10 A range: (2.5% rdg + 30 dgts) Auto/ Manual Ranging Crest Factor 3 AC coupled True RMS Specified from 10% to 100% of range Voltage Burden 40 mA, 10 A ranges: 0.2V 400 mA range: 1 V Input Protection 0.5 A/500 V & 10 A/500 V fast blow ceramic fuses 10A Input 10 A for 60 sec max. followed by a 10 minute cooling period Resistance Ranges 400 , 4 k, 40 k, 400 k, 4 M, 40 M Resolution 0.01 , 0.1 , 1.0 , 10 , 1 k, 10 k Accuracy 400 range: (0.3% rdg + 15dgts) 4 k to 400 k ranges: (0.3% rdg + 5dgts) 4 M range: (0.5% rdg +10 dgts) 40 M range: (1.5% rdg + 20 dgts) Open Circuit Voltage (typical) 1.2 Vdc (2.5 Vdc on 400 range) Overload Protection 500 VDC/ACrms Select between Auto or Capacitance Manual ranging Ranges 4 nF, 40 nF, 400 nF, 4 uF, 40 uF Resolution 1 pF, 10 pF, 100 pF, 1 nF, 10 nF Accuracy 4 nF range: (3.0% rdg + 20 dgts) The 2712 is a full featured auto ranging true RMS DMM that combines 40 nF to 400 nF ranges: (3.0% rdg + 5 dgts) 4 uF to 20 uF (3.0% rdg + 5 dgts) performance, value and functionality. The 40000 count LCD has a green back 20 uF to 40 uF (5.0% rdg + 5 dgts) light that allows the meter to be used in dimly lit environments. The 2712 can Overload Protection 500 VDC/ACrms measure resistance values up to 40 Mohm and capacitance to 40 uF. With the Frequency Ranges 100 Hz, 1 kHz, 10 kHz, 100 kHz, 500 kHz auto power off feature you wont have to worry about accidental battery Resolution 0.01 Hz, 0.1 Hz, 1 Hz, 10 Hz, 100 Hz consumption. Value-packed features make this meter a must in everyTool Kit. Accuracy (0.1 % rdg + 10 dgts) Sensitivity 5 Hz-100 kHz: >500 mVrms, 100 kHz-500 kHz: >1.5 Vrms Minimum Pulse Width >2 us Duty Cycle Limits >30 % and <70 % Specifications model Overload Protection 500 VDC/AC rms 2712 Diode Test Test Current 0.8 mA (typical) DC Volts Resolution 0.1 mV Ranges 400 mV, 4 V, 40 V, 400 V, 1000 V Accuracy (1.5 % rdg + 10 dgts) Resolution 0.01 mV, 1 mV, 10 mV, 100 mV, 1 V Open Circuit Voltage 3.0 VDC (typical) Accuracy 400 mV range: (0.15 % rdg + 10 dgts) Overload Protection 500 VDC/ACrms 4 V to 1000 V ranges: (0.1 % rdg + 5 dgts) Continuity Input Impedance 400 mV: >3 M 4 V to 1000 V: 2.3 M Audible Indication Less than 40 Overload Protection 1000 VDC or 750 VACrms Response Time 500 ms AC Volts (True RMS) (45 Hz-1 kHz) Overload Protection 500 VDC/ACrms Ranges 400 mv, 4 V, 40 V, 400 V, 750 V General Resolution 0.01 mV, 1 mV, 10 mV, 100 mV, 1 V Display 4 3/4 digit, 40000 count LCD Accuracy 400 mV to 400 V ranges: (1.2% rdg + 20dgts) 45 ~ 60 Hz Analog Bargraph 40 segments with measurements of 20 times per second 4 V range: (1.5% rdg + 20 dgts) 60 ~ 500 Hz Polarity Automatic, positive implied, negative polarity indication 40 V to 400 V ranges: (1.5% rdg + 20dgts) 60 ~ 1 kHz Overrange MSD (Most Significant Digit) Blinks 750 V range: (2.0% rdg + 20 dgts) 45 ~ 500 Hz Low Battery Indication Battery symbol will display when battery voltage drops below AC + DC Volts (True RMS) (45 Hz-1 kHz) operating levels Ranges 400 mv, 4 V, 40 V, 400 V, 750 V Measurement Rate 2 times per second Resolution 0.01 mV, 1 mV, 10 mV, 100 mV, 1 V Auto Power Off Approximately 30 minutes Accuracy 400 mV to 400 V ranges: (1.5% rdg + 20dgts) 45 ~ 60 Hz Operating Environment 0C to 50C at <70 % relative humidity 4 V range: (2.0% rdg + 20 dgts) 60 ~ 500 Hz Storage Environment -20C to 60C at 0 to 80 % relative humidity 40 V to 400 V ranges: (2.0% rdg + 20dgts) 60 ~ 1 kHz Accuracies Stated accuracy at 23C +5C at <75 % relative humidity 750 V range: (2.0% rdg + 20 dgts) 45 ~ 500 Hz Temperature Coefficient 0.1 x (specified accuracy) per C. (C to 18C, 28C to 50C) Crest Factor 3 Power Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 AC coupled True RMS Specified from 10% to 100% of range Battery Life 150 hours typical Input Impedance 400 mV: >3 M 4 V to 750 V: 2.3 M Dimensions 165 mm (H) x 78 mm (W) x 42.5 mm (D) Overload Protection 1000 VDC or 750 VACrms Weight Approximately 10 oz. (285 g) with battery and hanger DC Current Three-Year Warranty Ranges 40 mA, 400 mA, 10 A Resolution 1 uA, 10 uA, 10 mA Supplied Accessories: User manual, one set of test leads, one spare fuse, and 9V battery (installed) Accuracy 40 mA to 400 mA ranges: (0.5% rdg + 10 dgts) Technical data subject to change www.bk precision.com B&K Precision Corp. 2013 Page 1 of 2 Tel.: 714.921.9095Data Sheet B&K Precisions 2700 Tool Kit Series Models 2703C, 2704C, 2705B, 2706B, 2707B, 2708B, 2709B & 2712 These excellent meters are for most jobs that require flexibility, accuracy and speed. Value-packed features make these meters a must for everyones Tool Kit . Common Features: DC Voltage to 1000V AC Voltage to 750V DC Current to 10A Continuity test Diode test Drop resistant case Magnetic hanging strap Magnetic Hanging Strap Single-handed operation The ergonomic design allows both left and right handed users to rotate the knob while holding the meter in one hand. While one hand keeps the probe on the circuit, the other hand changes the meters function. This speeds up troubleshooting because you dont have to locate the probe point in the circuit again. This convenient feature allows you to hang your DMM on any magnetic metallic surface freeing up your hands for troubleshooting. Back Light / Easy-to-Read LCD Model 2706B Models 2709B & 2712 Ultra-bright blue LCD Large easy-to-read LCD back light for low ambient with green LED backlight light measurements Features models 2712 2709B 2708B 2707B 2706B 2705B 2704C 2703C Ranging Auto/Manual Auto/Manual Auto/Manual Manual Manual Auto/Manual Manual Manual True RMS AC + DC - -- - Current 10 A AC/DC 10 A AC/DC 10 A AC/DC 10 A AC/DC 200 mA AC/DC 10 A AC/DC 10 A AC/DC 10 A DC Capacitance to 40 uF to 66 mF - to 20 uF to 20 mF - to 20 uF - Transistor Test -- - -- - Frequency Counter to 500 kHz to 66 MHz - to 20 MHz to 40 kHz - to 20 MHz - Temperature -- - - -- - Logic Probe -- - -- - Backlight LCD -- -- - Analog Bar Graph - -- -- - Battery Test -- - - - - - Auto Power off - -- Page 2 of 2 v041113 www.bk precision.com