5390 5380 5370 5360 The 5300 Series handheld DMM is the most advanced digital mul- timeter available in this price range. These meters incorporate a special 50,000 count integrated circuit for high-accuracy (0.025%) basic accuracy, high-reliability design. Measure AC Volts (True RMS AC, AC + DC), Resistance, Capacitance and Frequency, in addition Features models to dB, Duty Cycle, Pulse Width, Power Line Disturbances and 5390 5380 5370 5360 Temperature. These meters also feature fuse and battery access Basic Functions without breaking a calibration seal, great for ISO facilities. All mod- Basic Accuracy 0.025% 0.05% 0.1% els offer Peak Hold, Hold, Relative Mode and Backlight. Voltage (Best Resolution) 750VAC/1000VDC 750VAC/1000VDC (10V) (100V) Precision 50,000 count instruments Current (Best Resolution) 10AAC/DC 10AAC/DC (10nA) (1A) 0.025% Basic DCV accuracy (Models 5380 and 5390) Frequency True RMS reading Temperature Probe Large LCD display provides easy readability, all test Duty Cycle Event Counter parameters in clear view. Backlight Best value of any DMM CE safety approved Specifications models 5390 5380 5370 AC VOLTAGE (Auto/Manual Ranging, True RMS) Modes: AC or AC+DC, selectable Accuracy at greater than 10% of range, 50,000 counts at Full Scale: Ranges DC to 1 kHz to 4 kHz to 10 kHz to 30 kHz to Input 1kHz 4 kHz 10 kHz 30 kHz 50 kHz Resolution Impedance 500 mV 0.3%R+30D 1%R+3D 5%R+30D Not specified 10V 10 M /100 pF or 1 G 5V 0.3%R+30D 1%R+3D 2%R+30D 2%R+30D 3%R+30D 100 V 11 M /100 pF 50V 0.3%R+30D 1%R+30D 2%R+30D 2%R+30D 3%R+30D1 mV 10 M /100 pF 500V 0.3%R+30D 1%R+30D 2%R+30D 2%R+30D 3%R+30D10 mV 10 M /100 pF 750V 0.3%R+30D Not specified 100 mV 10 M /100pF 50 kHz to 100 kHz (5V, 50 V, 500 V ranges): 6% FS typical Crest Factor: 6 model 5360 Accuracy at greater than 10% of range, 5,000 counts at Full Scale: Ranges DC to 1kHz 1 kHz to 5 kHz to 10kHz to 20 kHz to Input 5 kHz 10 kHz 20 kHz 30 kHz Resolution Impedance 500 mV 1%R+3D 4%R+3D Not specified 100V 10 M /100 pF 5V 1%R+3D 1%R+3D 2%R+30D 2%R+3D 3%R+3D 1m V 11 M /100 pF 50V 1%R+3D 1%R+3D 2%R+3D 2%R+3D 3%R+3D 10m 10 M /100 pF 500V 1%R+3D 1%R+3D 2%R+3D 2%R+3D 3%R+3D 100 mV 10 M /100 pF 750V 1%R+3D Not specified 1 V 10 M /100pF Crest Factor: 3 28Specifications models 5390 5380 5370 5360 Unless otherwise stated, accuracy specifications apply from 18C to 28C. Specifications stated as n%R+nD, mean (n% of reading +n least significant digits). Accuracy specifications stated as n%FS, mean (n% of Full Scale) DC VOLTAGE (Auto Manual Ranging) Input Ranges Accuracy Resolution Impedance 500 mV 0.025%R+2D 0.025%R+2D 0.05%R+2D 0.1%R+2D 10 V 10 M or 1 G * 5V 0.025%R+2D 0.025%R+2D 0.025%R+2D 0.05%R+2D 0.1%R+2D 11 M 50V 0.025%R+2D 0.025%R+2D 0.05%R+2D 0.1%R+2D 1 mV 10 M 500V 0.025%R+2D 0.025%R+2D 0.05%R+2D 0.2%R+2D 10 mV 10 M 1000V 0.025%R+2D 0.025%R+2D 0.05%R+2D 0.3%R+2D 100 mV 10 M *(10 M only on 5360) AC/DC VOLTAGE PROTECTION Overvoltage Protection 1100 V DC + AC Peak Transient Protection 6kV for 10 s DC CURRENT (Auto/Manual Ranging) Max Burden Ranges Accuracy Resolution Voltage 500A 0.2%R+5D Not Available 10 nA 700 mV 5 mA 0.2%R+2D 0.2%R+2D 100 nA 700 mV 50mA 0.05%R+2D 0.2%R+2D 1 A 700 mV 500 mA 0.2%R+2D 0.2%R+2D 10 A 1.5 V 10 A 0.5%R+2D 0.3%R+2D 1 mA 500 mV models model 5390 5380 5370 5360 AC CURRENT (Auto/Manual Ranging, True RMS) AC or AC + DC AC CURRENT Accuracy at greater than 10% of range, 50,000 counts at Full Scale: Accuracy at greater than 10% of range, 5,000 counts at Full Scale: 1 kHz to 10 kHz to 20 kHz to Input Ranges DC to 1kHz 10 kHz 20 kHz 30 kHz Resolution Impedance Ranges DC to 5 kHz Resolution Max Burden Voltage 500 A 0.75%R+50D 0.75%R+50D 1.0%R+50D 3.0%R+50D 10 nA 700 mV 5 mA 1.0%R+3D 1 A 700 mV 5 mA 0.6%R+50D 0.6%R+50D 1.0%R+50D 2.0%R+50D 100 nA 700 mV 50 mA 1.0%R+3D 10 A 700 mV 50 mA 0.6%R+50D 0.6%R+50D 1.0%R+50D 2.0%R+50D 1 A 700 mV 500 mA 1.0%R+3D 100 mA 1.5 V 500 mA 0.7%R+50D 0.7%R+50D Not specified 10 A 1.5 V 10 A 1% of FS 10 mA 500 mV 10 A 1% of FS Not specified 1 mA 500 mV Crest Factor: 3 Crest Factor: 6 models models 5390 5380 5370 5360 5390 5380 5370 5360 CAPACITANCE (Auto/Manual Ranging) RESISTANCE (Auto/Manual Ranging) Max Accuracy Measurement Measurement Accuracy Range Resolution Current TIme Ranges Resolution Test Current 50 nF 1.0%R+2D 1.0%R+2D 10 pF 100 nA 0.5 sec 500 0.07%R+5D 0.1%R+5D 10 m 1 mA 500 nF 1.0%R+2D 1.0%R+2D 100 pF 1 A 0.5 sec 5 k 0.07%R+2D 0.1%R+2D 100 m 100 A 5 pF 1.0%R+2D 1.0%R+2D 1 nF 10 A 0.5 sec 50 k 0.07%R+2D 0.1%R+2D 1 10 A 50 F 1.0%R+2D 1.0%R+2D 10 nF 100 A 0.5 sec 500 k 0.07%R+2D 0.1%R+2D 10 1 A 500 F 1.0%R+2D 1.0%R+2D 100 nF 1 mA 1.5 sec 5 M 0.3%R+2D 0.3%R+2D 100 100 A 5000 F 1.0%R+2D 2.0%R+2D 1 F 1 mA 3 sec/ mF 50 M 1.0%R+2D 1.0%R+2D 1 k 10 A 50 mF 1.0%R+2D 2.0%R+2D 10 F 1mA 3 sec/ mF models Accessories 5390 5380 5370 5360 SUPPLIED: FREQUENCY (Autoranging) Test Leads, Spare Fuses, Instruction Manual Range: 0.6 Hz to 500 kHz Accuracy: (0.03% rdg+1 digit) OPTIONAL: 500 mV 5V to 500 V 750 V 10 A TL-130A General Purpose DMM Kit Ranges (5390, 5370) 500 A to 500 mA (5390, 5370) TP-5300 Platinum Temperature Probe (for 5370) 0.6Hz to 5kHz 2% of FS 2% of FS 100 V 2 A AK-5350 Calibration Software (AK-5300 Hardware required) 5 kHz to 50 kHz 5% of FS 5% of FS 250 V Not specified AK-5300 Communications Hardware & LabView drivers 50 kHz to 500 kHz Not specified 10% of FS Not specified Common Features CONTINUITY - Threshold: 10 to 20 Computer Interface: RS232 capability built-in. Requires AK-5300 DIODE TEST - Measures forward voltage drop of diode 0 to 1.999V GENERAL dB MEASUREMENT - 5390 and 5370 - Measures value relative to a reference from 1 to 9999 , 5380 at 600 Display: 50,000 count resolution LCD, 0.55 (14mm) digit height, PEAK HOLD - Selection: Peak + or Peak- (surge or sag) Acq. Time: <1rms 34 segment analog bargraph DUTY CYCLE: 5390, 5370, 5360-Modes: Selectable %+ ,or %- Min Measurement Rate: 2/sec., 20/sec - bargraph EVENT COUNTER (Model 5390) - Range: 0 to 99999 (Totalize) Power: 9V (NEDA 1604) Battery Life: 500 hrs MIN PULSE DURATION: 2 s Dimensions: 1.57 x 3.23 x 7.44 (40 x 82 x 189mm) PULSE WIDTH (Model 5390) Modes: Selectable +, - Min. Pulse Width: 20s Max Pulse Period: 12.5 s Weight: 14 oz (397g) TEMPERATURE (Model 5370) Using Model TP-5300 Probe (Optional) Three Year Warranty RANGE: -200 to +800C 29 For your nearest distributor, call 800-462-9832 or www.bkprecision.com