Installation Q25 Sensors dc-Voltage Series Guide Self-contained, dc-operated sensors Additional information on this product is immediately available online at www.bannerengineering.com/116165 View or download additional information, including excess gain curves, beam patterns and accessories. For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767. Sensing Mode Range LED Output Model* Q256E Infrared Opposed 20 m (66 ) NPN Q25SN6R 950 nm PNP Q25SP6R Polarized Visible NPN Q25SN6LP Retro- 2 m (79 ) Red P PNP Q25SP6LP reflective 680 nm NPN Q25SN6FF25 25 mm (1 ) R cutoff LISTED PNP Q25SP6FF25 Cabled Emitters NPN Q25SN6FF50 Fixed 50 mm (2 ) Infrared Field cutoff 880 nm bn + PNP Q25SP6FF50 10-30V dc bu NPN Q25SN6FF100 100 mm (4 ) cutoff PNP Q25SP6FF100 QD Emitters * Standard 2 m (6.5 ) cable models are listed. bn + 10-30V dc 9 m (30 ) cable: add suffix W/30 (e.g., Q256E W/30). bu 4-pin Euro-style QD models: add suffix Q (e.g., Q256EQ). A model with a QD connector requires a bk mating cable. No Connection wh Dimensions NPN (Sinking) Outputs QD Models Cabled Models Standard Hookup bu Yellow LED 10 - 30V dc Output Indicator bn + 30.0 mm* bk (1.18 ) Load Green LED wh Load 25.0 mm Power Indicator (0.98 ) 35.0 mm Lens Centerline Alarm Hookup (1.38 ) 12.4 mm bn (0.49 ) 10 - 30V dc bu + bk Load wh 15.2 mm Alarm (0.60 ) 12.7 mm *Fixed-field models = 31.0 mm (1.22 ) M18 x 1 Thread (0.50 ) (Jam Nut Supplied) PNP (Sourcing) Outputs Standard Hookup 2 m (6.5 ) Cable bn + 10 - 30V dc bu bk Load WARNING . Not To Be Used for Personnel Protection wh Load Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death. These sensors do Alarm Hookup NOT include the self-checking redundant circuitry necessary to allow their use in bu + 10 - 30V dc bn personnel safety applications. A sensor failure or malfunction can cause either bk Load an energized or de-energized sensor output condition. Consult your current wh Alarm Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection. NOTE: QD hookups are functionally identical. Printed in USA 10/04 P/N 116165 Q25 Sensors dc-Voltage Series Specications Supply Voltage and Current (exclusive of load current): 10 to 30V dc (10% max. Repeatability ripple) supply current (exclusive of load current): Opposed mode: 375 s Emitters: 25 mA Polarized Retr o and Fixed-Field: 750 s Receivers: 20 mA Repeatability and response are independent of signal strength. Polarized Retroreflective: 30 mA Indicators Fixed-Field: 35 mA Two LEDs (Green and Yellow) Supply Protection Circuitry Green ON steady: power to sensor is ON Protected against reverse polarity and transient voltages Green flashing: output is overloaded Output Configuration Yellow ON steady: N.O. output is conducting SPDT solid-state dc switch Choose NPN (current sinking) or PNP (current Yellow flashing: excess gain marginal (1 to 1.5x) in light condition sourcing) models Construction Light Operate: N.O. output conducts when sensor sees its own (or the PBT polyester housing polycarbonate (opposed-mode) or acrylic lens emitters) modulated light Environmental Rating Dark Operate: N.C. output conducts when the sensor sees dark the N.C. Leakproof design rated NEMA 6P, DIN 40050 (IP69K) (normally closed) output may be wired as a normally open Connections marginal signal alarm output, depending upon hookup to power 2 m (6.5 ) or 9 m (30 ) attached cable, or 4-pin Euro-style quick-disconnect supply (U.S. patent 5087838) fitting Output Rating Operating Conditions 150 mA maximum (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA. Temperature: -40 to +70C (-40 to +158F) Maximum relative humidity: 90% at 50C (non-condensing) OFF-state leakage current: < 1 microamp 30V dc ON-state saturation voltage: < 1V at 10 mA dc < 1.5V at 150 mA dc Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements. Method 201A (Vibration Output Protection Circuitry Protected against false pulse on power-up and continuous overload or short frequency 10 to 60 Hz, max., double amplitude 0.06 acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating 100G for circuit of outputs non-operation) Output Response Time Certifications Opposed mode: 3 ms ON, 1.5 ms OFF Polarized Retro and Fixed-Field: 3 ms ON and OFF R NOTE: 100 ms delay on power-up outputs do not conduct during this time. LISTED Quick-Disconnect (QD) Cables Style Model Length Dimensions Pinout 15 mm 4-pin MQDC-406 2 m (6.5 ) (0.6 ) Euro-style MQDC-415 5 m (15 ) M12 x 1 44 mm max. Straight MQDC-430 9 m (30 ) White Wire (1.7 ) Brown Wire Blue Wire 38 mm max. (1.5 ) Black Wire 4-pin MQDC-406RA 2 m (6.5 ) 38 mm max. (1.5 ) Euro-style MQDC-415RA 5 m (15 ) Right-angle MQDC-430RA 9 m (30 ) M12 x 1 15 mm (0.6 ) Additional information on this product is immediately available online at www.bannerengineering.com/116165 View or download additional information, including excess gain curves, beam patterns and accessories. For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767. WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 116165 Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 Phone: 763.544.3164 www.bannerengineering.com Email: sensors bannerengineering.com