Installation S18 Sensors ac-Voltage Series Guide Self-contained, ac-operated sensors Additional information on this product is immediately available online at www.bannerengineering.com/116160 View or download additional information, including excess gain curves, beam patterns and accessories. For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767. Sensing Mode Range LED Output Model* S183E 20 m Opposed LO S18AW3R (66 ) Infrared DO S18RW3R 950 nm LO S18AW3L Retro- reflective DO S18RW3L 2 m Polarized (79 ) Visible LO S18AW3LP Retro- Red P DO S18RW3LP reflective 680 nm R LO S18AW3D LISTED 100 mm (4 ) DO S18RW3D Cabled Emitters Diffuse LO S18AW3DL 300 mm bn (12 ) DO S18RW3DL 20-250V ac bu LO S18AW3FF25 25 mm (1 ) Infrared cutoff 880 nm DO S18RW3FF25 QD Emitters LO S18AW3FF50 Fixed 50 mm (2 ) (4-pin Micro-Style) Field cutoff DO S18RW3FF50 rd/bk LO S18AW3FF100 100 mm (4 ) 20-250V ac rd/wh cutoff DO S18RW3FF100 rd No Connection gn * Standard 2 m (6.5 ) cable models are listed. 9 m (30 ) cable: add suffix W/30 (e.g., S183E W/30). 4-pin Micro-style QD models: add suffix Q1 (e.g., S183EQ1). A model with a QD connector requires a mating cable. All Other Cabled Models Use polarized models when shiny objects will be sensed. bn Dimensions 20-250V ac bu QD Models Cabled Models bk Load Yellow LED Yellow LED Output Indicator Output Indicator Green LED Power Indicator Green LED All Other QD Models Power Indicator (4-pin Micro-Style) rd/bk 20-250V ac rd/wh 63.2 mm rd 63.2 mm 104.1 mm* Load 85.3 mm* (2.49 ) (2.49 ) (4.10 ) (3.36 ) gn No Connection *Polarized retro and fixed-field models = 86.3 mm (3.40 ) *Polarized retro and fixed-field models = 105.1 mm (4.14 ) WARNING . Not To Be Used for Personnel Protection Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death. These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection. Printed in USA 10/04 P/N 116160 S18 Sensors ac-Voltage Series Specications Supply Voltage and Current Repeatability 20 to 250V ac (50/60 Hz). Average current: 20 mA Opposed Mode: 2 milliseconds Peak current: 200 mA at 20V ac, 500 mA at 120V ac, 750 mA at 250V ac Other Models: 4 milliseconds Supply Protection Circuitry Repeatability and response are independent of signal strength. Protected against transient voltages Indicators Output Configuration Two LEDs (Green and Yellow) SPST solid-state ac switch Three-wire hookup Choose light operate or dark Green ON steady: power to sensor is ON Yellow ON steady: sensor sees light operate models Light Operate: Output conducts when sensor sees its own (or the emitters) Yellow flashing: excess gain marginal (1 to 1.5x) in light condition modulated light Construction Dark Operate: Output conducts when the sensor sees dark PBT polyester housing polycarbonate (opposed mode) or acrylic lens Output Rating Environmental Rating Leakproof design rated NEMA 6P, DIN 40050 (IP69K) 300 mA maximum (continuous) Fixed-Field Models: derate 5 mA/C above +50C (+122F) Connections Inrush Capability 1 amp for 20 milliseconds, non-repetitive 2 m (6.5 ) attached cable, or 4-pin Micro-style quick-disconnect fitting OFF-state leakage current: < 100 microamps Operating Conditions ON-state saturation voltage: 3V at 300 mA ac 2V at 15 mA ac Temperature: -40 to +70C (-40 to +158F) Output Protection Circuitry Maximum relative humidity: 90% at 50C (non-condensing) Protected against false pulse on power-up Vibration and Mechanical Shock Output Response Time All models meet Mil. Std. 202F requirements. Method 201A (Vibration Opposed Mode: 16 milliseconds ON, 8 milliseconds OFF frequency 10 to 60 Hz, max., double amplitude 0.06 acceleration 10G). Other Models: 16 milliseconds ON and OFF Method 213B conditions H&I (Shock: 75G with unit operating 100G for NOTE: 100 millisecond delay on power-up non-operation) Certifications R LISTED Quick-Disconnect (QD) Cables Style Model Length Dimensions Pin-Out 4-pin MQAC-406 2 m (6.5 ) Micro-style MQAC-415 5 m (15 ) Green Wire Straight MQAC-430 9 m (30 ) Red Wire Red/Black 38 mm max. Red/White Wire (1.5 ) Wire 4-pin MQAC-406RA 2 m (6.5 ) 38 mm max. (1.5 ) Micro-style MQAC-415RA 5 m (15 ) Right-angle MQAC-430RA 9 m (30 ) 1/2-20UNF-2B 15 mm (0.6 ) Additional information on this product is immediately available online at www.bannerengineering.com/116160 View or download additional information, including excess gain curves, beam patterns and accessories. For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767. WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 116160 Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 Phone: 763.544.3164 www.bannerengineering.com Email: sensors bannerengineering.com