www.Amprobe.eu AM-500-EUR Series AM-510-EUR AM-520-EUR Digital Multimeters AM-510-EUR, AM-520-EUR, AM-530-EUR, AM-540-EUR and AM-550-EUR Announcing the Amprobe AM-500-EUR Digital Multimeter Series, a full line of digital multimeters that offer functions for every application. These tough meters are designed to be a reliable, feature-rich, and rugged solution for AM-530-EUR AM-540-EUR taking critical measurements in residential, HVAC, electrical and industrial AM-550-EUR settings at breakthrough affordability. AM-500-EUR sERiEs sEEl ction gUidE AM-510-EUR AM-520-EUR AM-530-EUR AM-540-EUR AM-550-EUR CAT III 600V CAT III 600V CAT IV 600V CAT IV 600V Measurement Category CAT III 600V CAT II 1000V CAT II 1000V CAT III 1000V CAT III 1000V Measure voltage in noisy environments True-rms Electrical panels, AC outlets AC Voltage (V) 600 750 750 1000 1000 DC systems, auto/marine batteries DC Voltage (V) 600 1000 1000 1000 1000 AC Current - electrical panels, appliances AC Current (A) 10 10 10 10 10 DC Current - electronics, DC motors DC Current (A) 10 10 10 10 10 Specified resistance and continuity Resistance (MOhms) 40 40 40 60 60 Flame sensors Microamps Diodes in ac to dc converters Diode test Fuses, lightbulbs, wire connections Continuity Household batteries Battery test Motor startup or run capacitors Capacitance Frequency verification Frequency TM VolTect Plus Non-contact voltage detection Non-contact voltage Electrical load-time on vs. time off Duty cycle Temp of air vents, fuses, transformers Temperature inputs 1 1 2 2 Automatically selects measurement range Autoranging Manually select measurement range Manual ranging Voltage on variable frequency drives Low pass filter Detect stray voltages Low Z Dimly lit areas Built-in flashlight Meter resolution LCD Counts 4,000 4,000 4,000 6,000 6,000 Dimly lit areas Backlight Monitoring fast changing signals Bar graph Two relative measurements on one screen Dual display Data memory Data hold Difference between two measurements Relative reading Max/min peak measurement Max/min hold Specialized signal measurements Peak hold (crest) For detailed specifications and ordering info go to www.amprobe.eu 4148103 A 2012 Amprobe Test Tools. All rights reserved. Events Display Features Functionswww.Amprobe.eu tEchnic Al dA t A AM-500-EUR sEREi s Model AM-510-EUR AM-520-EUR AM-530-EUR AM-540-EUR AM-550-EUR General Specifications Display 3999 Digits 3999 Digits 3999 Digits 5999 Digits 5999 Digits Measurement ranges AC voltage 1 mV...600V 1 mV...750V 1 mV...750V 1 mV...1000 V 1 mV...1000 V Basic accuracy * (1.0 % rgd. + 3 digits) (1.0 % rgd. + 3 digits) (1.0 % rgd. + 3 digits) (1.0 % rgd. + 3 digits) (1.0 % rgd. + 3 digits) Frequency range 45 Hz...400 Hz 45 Hz...400 Hz 45 Hz...400 Hz 45 Hz...1 kHz 45 Hz...1 kHz DC voltage 1 mV...600V 0.1 mV...1000 V 0.1 mV...1000 V 0.1 mV...1000 V 0.1 mV...1000 V Basic accuracy * (0.8 % rgd. + 1 digits) (0.8 % rgd. + 1 digits) (0.8 % rgd. + 1 digits) (0.5 % rgd. + 2 digits) (0.5 % rgd. + 2 digits) Input resistance 10 M 10 M 10 M 10 M 10 M Current AC 0.1 A...10A 0.1 A...10A 0.1 A...10A 0.1 A...10A 0.1 A...10A Basic accuracy * (1.2 % rgd. + 2 digits) (1.2 % rgd. + 2 digits) (1.2 % rgd. + 2 digits) (1.2 % rgd. + 2 digits) (1.2 % rgd. + 2 digits) Frequency range 45 Hz...400 Hz 45 Hz...400 Hz 45 Hz...400 Hz 45 Hz...1 kHz 45 Hz...1 kHz Current DC 0.1 A...10A 0.1 A...10A 0.1 A...10A 0.1 A...10A 0.1 A...10A Basic accuracy * (1.0 % rgd + 2 digits) (1.0 % rgd + 2 digits) (1.0 % rgd + 2 digits) (1.0 % rgd + 2 digits) (1.0 % rgd + 2 digits) Resistance 0.1 ...40 M 0.1 ...40 M 0.1 ...40 M 0.1 60 M 0.1 60 M Basic accuracy * (1.2 % rgd. + 2 digits) (1.2 % rgd. + 2 digits) (1.2 % rgd. + 2 digits) (1.2 % rgd. + 2 digits) (1.2 % rgd. + 2 digits) Continuity R < 10 R < 10 R < 10 R < 10 R < 10 Capacitance 10 pF...100.0 F 10 pF...4000 F 10 pF...4000 F 60.00 nF...60 mF 60.00 nF...60 mF Basic accuracy * (3 % rgd. + 5 digits) (3 % rgd. + 5 digits) (3 % rgd. + 5 digits) (3 % rgd. + 5 digits) (3 % rgd. + 5 digits) Frequenz 1,00 Hz...10 MHz 1,00 Hz...10 MHz 1,00 Hz...10 MHz 1,00 Hz...60 MHz 1,00 Hz...60 MHz Basic accuracy * (0.1 % rgd. + 4 digits) (0.1 % rgd. + 4 digits) (0.1 % rgd. + 4 digits) (0.1 % rgd. + 3 digits) (0.1 % rgd. + 3 digits) Temperature - -40...1000 C -40...1000 C -40...1000 C -40...1000 C Basic accuracy * - (1.0 % rgd. + 8 digits) (1.0 % rgd. + 8 digits) (1.0 % rgd. + 8 digits) (1.0 % rgd. + 8 digits) CAT III / 600V, CAT III / 600V, CAT III / 600V, CAT III / 600V, Measurement category CAT III / 600V CAT II / 1000V CAT II / 1000V CAT II / 1000V CAT II / 1000V Pollution degree 2 Safety EN 61010, IEC 61010 Power supply 9 V (6F22) Dimensions 182 x 90 x 45 mm Weight approx. 354 g (incl. battery) 2 x test leads, 2 x test leads, 2 x test leads, 2 x test leads, 2 x test leads, 2 x temperature probe, 2 x temperature probe, 1 x temperature probe, 1 x temperature probe, Scope of supply 1 x 9 V battery, 1 x temperature adaptor 1 x temperature adaptor 1 x strap, 1 x 9 V battery, 1 x strap, 1 x 9 V battery, 1 x user manual 1 x strap, 1 x 9 V battery, 1 x strap, 1 x 9 V battery, 1 x user manual 1 x user manual 1 x user manual 1 x user manual * Basic accuracy refers to the best accuracy in the respective function oRdER infoRMA tion Order number Description AM-510-EUR Digital Multimeter AM-520-EUR Digital Multimeter AM-530-EUR Digital Multimeter TRMS AM-540-EUR Digital Multimeter AM-550-EUR Digital Multimeter TRMS Amprobe Amprobe Europe info amprobe.com In den Engematten 14, Everett, WA 98203 79286 Glottertal, Germany Tel: 877-AMPROBE (267-7623) Tel.: +49 (0) 7684 8009 - 0 For detailed specifications and ordering info go to www.amprobe.eu 4148103 A 2012 Amprobe Test Tools. All rights reserved.