Data Sheet HD160C Heavy-Duty Digital Multimeter Rugged autoranging meter with true-rms Highest voltage capability, measuring to 1500 Vdc and 1000 Vac CAT IV 1000 V rated Key features: Special sealing for environment Measures 1500 VDC and water resistance. IP67 rated CAT IV 1000 V Constructed with drop-resistant IP67 Rated housing and PCB mounting Measures capacitance, Temperature, Frequency temperature and frequency & Capacitance Superior 10,000 count resolution Magne-Grip holster with bar graph with magnetic hanging Magne-Grip holster, frees both strap hands for work Includes high voltage test leads with threaded alligator clips No hassle Temperature measurement built-in warranty Frequency and capacitance Digi-Glo bright backlight No waiting. No shipping The HD160C is designed for profes- charges. sional use in harsh environments. The meter is unusually rugged and Our commitment to reliable in everyday heavy use ap- high-quality products plications. The meter is made using and customer service waterproof construction to prevent is demonstrated by dirt, grime and moisture from enter- our industry exclusive HD160C ing the case and causing inaccurate No Hassle warranty. readings or damaging shorts. In the unlikely event Built of tough, fire-retardant that an Amprobe Test thermoplastic resistant to grease Tool requires warranty and chemical spills, with all sensi- service, any of our tive components shock-mounted for local dealers are a drop resistance to at least eight authorized to replace feet. it, on the spot. Model HD160C has an extended voltage measurement capability of 1500 V dc and 1000 V ac, unmatched by any other line of digital multime- N10140 ters. The extended voltage ranges can withstand transients up to 12 kV. www.Amprobe.com Amprobe Test Tools www.Amprobe.comHD160C Technical Specifications Data Sheet General Specifications Display 4 digit LCD, 9999 counts, with annunciators, menu features and 41 segment bargraph. Polarity Indication Automatic Input overload indication OL, -OL. Low Battery Indication B less than 50 hours battery life remain, accuracy is no longer guaranteed Display Update Rate 2/sec, nominal 20/sec for bargraph. Oper. Temp. 0 C to +50 C 0 to 75 % R.H. Storage Temp. -20 C to 60 C 0 to 80 % RH, battery removed Altitude 2000 meters - indoor use Temperature coefficient 0.1 x (spec. accuracy)/C (0 C to 18 C and 28 C to 50 C) Fuse F 2 A/1500 V fuse (8 mm x 65 mm), I.R. 30 kA Amprobe p/n FP700 Power Standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 Auto Power-Down Meter powers down after approximately 30 minutes of inactivity. Not in Min/Max function. Battery Life (typical) 150 hours, alkaline. Backlight usage consumes extra power and will decrease battery life significantly. Backlight auto-off after approx. 60 seconds. Dimensions, without holster (H x W x D) 200 x 102 x 59 mm (7.9 in x 4.0 in x 2.3 in) Weight (incl. battery) 642 g (22 oz) Accessories Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (installed), hex wrench (inside holster), Holster with Magne-Grip strap, Type K thermocouple probe (TP255), Tempera- ture Adaptor (TA-1A) and User Manual. Case material Reinforced, high-impact, fire retardant thermoplastic Safety Meets EN 61010-1 CCAATT IIVV 11000000 V (V (11550000 V DV DCC mmaaxx)) CCllaassss IIII,, EENN 6600552299::IIPP6677 EMC Meets EN 61326-1 Electrical Specifications (Accuracy at 23 C 5 C, <75 % RH, guaranteed for one year.) Function Range Accuracy DC Volts Ranges 1000 mV, 10 V, 100 V, 1500 V Resolution 0.1 mV in 1000 mV range Accuracy (0.1 % rdg + 5 dgt) Input Impedance 10 M CMRR >120 dB up to 1500 V dc NMRR >60 dB at 50 or 60 Hz OL Protection 1500 V dc or 1000 V ac rms. Transient protection 12 kV impulse (1.2 S/50 S) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V/1500V dc product. This product should not be used in installations where transients exceed 12 kV. AC Volts True rms Ranges 1000 mV, 10 V, 100 V, 1000 V Resolution 0.1 mV in 1000 mV range Accuracy 1000 mV (45 Hz to 400 Hz) (1.2 % rdg + 10 dgt) 10 V, 100 V (45 Hz to 500 Hz) (1.2 % rdg + 10 dgt) 10 V, 100 V (500 Hz to 2 kHz) (2.0 % rdg + 10 dgt) 1000 V (45 Hz to 1 kHz) (2.0 % rdg + 10 dgt) Input Impedance 10 M Conversion type True rms, ac coupled 5 % to 100 % of range Crest factor 3 OL Protection 1500 V dc or 1000 V ac rms Transient protection 12 kV impulse (1.2 S/50 S) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV Amprobe Test Tools