Product: 10GX12 10GX Category 6A Enhanced Cable, 4 Pair, U/UTP, CMR Product Description 10GX Category 6A Enhanced Premise Horizontal Cable (625MHz), 4 Pair, 23 AWG Solid Bare Copper Conductors, U/UTP, Riser-CMR, PVC Jacket Technical Specifications Product Overview Suitable Applications: Premise Horizontal Cable, Ethernet up to 10GBASE-T, HDBaseT, PoE++, PoE+, PoE Patent: This product has one or more applicable patents. More information on patents can be found at . 200 27.6 dB/100m 38.8 11.2 22.8 18.0 100 22 Ohm 100 10 Ohm 59.0 33.2 27.0 250 31.1 dB/100m 37.3 6.3 20.8 17.3 100 32 Ohm 100 10 Ohm 57.5 31.2 26.0 300 34.3 dB/100m 36.1 1.9 19.3 16.8 100 32 Ohm 100 10 Ohm 56.3 29.7 25.2 350 37.2 dB/100m 35.1 17.9 16.3 100 32 Ohm 100 10 Ohm 55.3 28.3 24.6 400 40.1 dB/100m 34.3 16.8 15.9 100 32 Ohm 100 10 Ohm 54.5 27.2 24.0 450 42.7 dB/100m 33.5 15.7 15.5 100 32 Ohm 100 10 Ohm 53.7 26.1 23.5 500 45.3 dB/100m 32.8 14.8 15.2 100 32 Ohm 100 10 Ohm 53.0 25.2 23.0 550 47.7 dB/100m 32.2 14.0 14.9 100 32 Ohm 100 10 Ohm 52.4 24.4 600 50.1 dB/100m 31.6 13.2 14.7 100 32 Ohm 100 10 Ohm 51.8 23.6 625 51.2 dB/100m 31.4 12.9 14.5 100 32 Ohm 100 10 Ohm 51.6 23.3 750 56.7 dB/100m 30.2 11.3 14.0 50.4 21.7 860 61.2 dB/100m 29.3 10.1 13.6 49.5 20.5 Voltage UL Voltage Rating 300 V (CMR), 300 V (CL3R) Mechanical Characteristics Temperature UL Temperature Operating Installation Storage 90C -20C To +75C 0C To +50C -20C To +75C Bend Radius Stationary Min. Installation Min. 1.25 in (31.8 mm) 3.0 in (76 mm) Max. Pull Tension: 25 lbs (11 kg) Bulk Cable Weight: 36 lbs/1000ft Standards and Compliance Environmental Riser, Indoor Suitability: Sustainability: Product Lens, Environmental Product Declaration (EPD) Available Flammability / UL 1666 Riser, FT4, FT4, IEC 60332-1-2 Reaction to Fire: CPR Compliance: CPR Euroclass: Eca NEC / UL Compliance: Article 800, CMR CMR-LP (0.5A) CL3R-LP (0.5A) CEC / C(UL) CMR Compliance: ICEA Compliance: S-116-732-2013 IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 NEMA Compliance: ANSI/NEMA WC-66 Data Category: Category 6A TIA/EIA Compliance: ANSI/TIA-568.2-D Category 6A ISO/IEC Compliance: ISO/IEC 11801-1, IEC 61156-5 CENELEC Segregation class according EN50174-2 = a Compliance: European Directive EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16 Compliance: APAC Compliance: China RoHS II (GB/T 26572-2011) Other Standard Verified Channel/Category 6A Compliance(s): Plenum Number: 10GX13 Product Notes Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values above 625 MHz are for Engineering Notes: Information Only. 0.295 Cable Dimension per TIA 6 1 Equivalent Diameter. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. History Update and Revision: Revision Number: 0.493 Revision Date: 12-15-2021 Variants Item Color Putup Type Length UPC 10GX12 0101000 Black Reel 1,000 ft 612825102168