Product: 1152A Broadband Coax, Series 6, 18 AWG Solid BCCS, Quad Shield, FEP Jkt, CMP Product Description Broadband Coax, Series 6, 18 AWG Solid Bare Copper Covered Steel Conductor, FEP Insulation, Foil + 60% Tinned Copper Braid + Foil + 40% Tinned Copper Braid Shield, FEP Jacket, CMP Technical Specifications Product Overview Suitable Applications: Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas Construction Details Series Type: 6 Conductor AWG Stranding Nom. Diameter Material 18 Solid 0.040 in BCCS - Bare Copper Covered Steel Insulation Material Nom. Diameter FEP - Fluorinated Ethylene Propylene (Foam) 0.170 in Outer Shield Material Layer Outer Shield Type Material Material Trade Name Coverage 1 Tape Tri-Laminate (Alum+Poly+Alum) Duobond II 100% 2 Braid Tinned Copper (TC) 60% 3 Tape Tri-Laminate (Alum+Poly+Alum) Duofoil 60% 4 Braid Tinned Copper (TC) 40% Outer Jacket Material Material Nom. Diameter FEP - Fluorinated Ethylene Propylene 0.273 in Electrical Characteristics Return Loss (RL) Frequency MHz Min. Structural Return Loss dB 5 - 400 MHz 20 dB Attenuation Frequency Nom. Attenuation dB/100ft 1 MHz 0.3 dB/100ft 10 MHz 0.66 dB/100ft 50 MHz 1.6 dB/100ft 100 MHz 2.2 dB/100ft 200 MHz 3.0 dB/100ft 400 MHz 4.6 dB/100ft 700 MHz 6.6 dB/100ft900 MHz 7.7 dB/100ft 1000 MHz 8.2 dB/100ft Electricals Nom. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance Cond-to-Shield Nom. Impedence 28 Ohm/1000ft 1.8 Ohm/1000ft 16.5 pF/ft 75 Ohm Voltage UL Voltage Rating 300 V (CMP) Mechanical Characteristics Temperature Operating -70C to +200C Bend Radius Installation Min. 2.7 in Bulk Cable Weight: 45 lbs/1000ft Max. Pull Tension: 192 lbs Standards and Compliance Environmental Suitability: Indoor - Plenum, Indoor, Outdoor, Burial Sustainability: CA Prop 65 Flammability / Fire Resistance: NFPA 262 NEC / UL Compliance: CMP CEC / C(UL) Compliance: CMP European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE) APAC Compliance: China RoHS II (GB/T 26572-2011) Other Standard Compliance(s): ANSI/SCTE 74 Product Notes Notes: For use in indoor plenum environments but also suitable for outdoor and underground applications. History Update and Revision: Revision Number: 0.337 Revision Date: 08-25-2020 2020 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.