Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1308A Multi-Conductor - Speaker Cable For more Information please call 1-800-Belden1 General Description: 16 AWG stranded (65x34) oxygen-free high-conductivity bare copper conductors, PO insulation, PVC jacket. Sequential footage marking every two feet. Usage (Overall) Suitable Applications: Intercom/PA Systems, Sound/Audio Systems Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material Dia. (mm) 4 16 65x34 High Conductivity BC - Bare Copper 1.4732 Total Number of Conductors: 4 Insulation Insulation Material: Insulation Material Dia. (mm) PO - Polyolefin 2.1082 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Overall Cable Overall Cabling Color Code Chart: Number Color 1 Black 2 Red 3 White 4 Green Overall Nominal Diameter: 6.858 mm Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +75C Bulk Cable Weight: 74.410 Kg/Km Max. Recommended Pulling Tension: 578.266 N Min. Bend Radius/Minor Axis: 69.850 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CL3, CM Page 1 of 3 01-30-2019Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1308A Multi-Conductor - Speaker Cable CEC/C(UL) Specification: CM EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 07/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Flame Test UL Flame Test: UL1581 Vertical Flame and FT-1 Flame Test CSA Flame Test: FT1 Suitability Suitability - Indoor: Yes Suitability - Outdoor: Yes Plenum/Non-Plenum Plenum (Y/N): No Plenum Number: 6202UE Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/m) 0.52496 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 65.2919 Nominal Velocity of Propagation: VP (%) 66 Nom. Conductor DC Resistance: DCR 20C (Ohm/km) 13.124 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 9 Amps per conductor 25C Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 1308A N3UU500 500 FT 26.500 LB GREEN, MIL 4 16 PE FRPVC 1308A 006U500 500 FT 26.500 LB BLUE, LIGHT 4 16 PE FRPVC 1308A 008U500 500 FT 26.500 LB GRAY 4 16 PE FRPVC 1308A 0081000 1,000 FT 54.000 LB GRAY C 4 16 PE FRPVC 1308A 010U500 500 FT 26.500 LB BLACK 4 16 PE FRPVC 1308A 0101000 1,000 FT 54.000 LB BLACK 4 16 PE FRPVC 1308A 1SLU500 500 FT 26.500 LB WHITE 1SL 4 16 PE FRPVC 1308A 1SL1000 1,000 FT 54.000 LB WHITE 1SL C 4 16 PE FRPVC Notes: Page 2 of 3 01-30-2019