Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1325A Multi-Conductor - Double-Pair Cable For more Information please call 1-800-Belden1 General Description: Security & Commercial Audio Cable, Plenum-CMP, 2-22 AWG stranded tinned copper pairs with Flamarrest insulation, individually shielded with Beldfoil shield, Flamarrest jacket Usage (Overall) Suitable Applications: Sound and Audio Systems, Intercom and PA Systems, Security Systems, Power-Limited Control Systems Physical Characteristics (Overall) Conductor AWG: Pairs AWG Stranding Conductor Material 2 22 7x30 TC - Tinned Copper Total Number of Conductors: 4 Insulation Insulation Material: Insulation Trade Name Insulation Material Flamarrest F-R PVC - Flame Retardant Polyvinyl Chloride Inner Shield Inner Shield Material: Inner Shield Trade Name Type Inner Shield Material Coverage (%) Beldfoil (Z-Fold) Tape Aluminum Foil-Polyester Tape 100 Inner Shield Drain Wire AWG: AWG 24 Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Flamarrest LS PVC - Low Smoke Polyvinyl Chloride Overall Cable Overall Nominal Diameter: 4.013 mm Pair Pair Color Code Chart: Number Color 1 Black & Red 2 White & Green Pair Lay Length & Direction: Twists (twist/m) 8 Mechanical Characteristics (Overall) Operating Temperature Range: 0C To +75C Bulk Cable Weight: 28.276 Kg/Km Page 1 of 3 01-30-2019Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1325A Multi-Conductor - Double-Pair Cable Max. Recommended Pulling Tension: 120.101 N Min. Bend Radius/Minor Axis: 40.640 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 05/30/2006 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Flame Test UL Flame Test: UL910 Steiner Tunnel CSA Flame Test: FT6 Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 8723 Electrical Characteristics (Overall) Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 111.554 Nom. Conductor DC Resistance: DCR 20C (Ohm/km) 48.2307 Nom. Inner Shield DC Resistance: DCR 20C (Ohm/km) 49.215 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2.8 Amps per conductor 25C Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 1325A D151000 1,000 FT 20.000 LB BLUE C 2 FS PR 22 FLRST FLRST 1325A 009Z1000 1,000 FT 22.000 LB WHITE 2 FS PR 22 FLRST FLRST 1325A 0091000 1,000 FT 20.000 LB WHITE 2 FS PR 22 FLRST FLRST 1325A 009500 500 FT 10.500 LB WHITE 2 FS PR 22 FLRST FLRST 1325A 010Z1000 1,000 FT 22.000 LB BLACK 2 FS PR 22 FLRST FLRST 1325A 010Z500 500 FT 12.500 LB BLACK 2 FS PR 22 FLRST FLRST 1325A 0101000 1,000 FT 20.000 LB BLACK 2 FS PR 22 FLRST FLRST 1325A 010500 500 FT 10.500 LB BLACK 2 FS PR 22 FLRST FLRST Page 2 of 3 01-30-2019