Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1590A Multi-Conductor - Category 5e Nonbonded-Pair Cable For more Information please call 1-800-Belden1 General Description: CAT5e (200MHz), 2-Pair, U/UTP-Unshielded, Plenum-CMP, Premise Horizontal Cable, 24 AWG solid bare copper conductors FEP insulation, Ripcord, Flamarrest jacket Usage (Overall) Suitable Applications: Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422 Physical Characteristics (Overall) Conductor AWG: Pairs AWG Stranding Conductor Material 2 24 Solid BC - Bare Copper Total Number of Conductors: 4 Insulation Insulation Material: Insulation Material FEP - Fluorinated Ethylene Propylene Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Flamarrest LS PVC - Low Smoke Polyvinyl Chloride Outer Jacket Diameter: Nom. Dia. (mm) 4.191 Outer Jacket Ripcord: Yes Pair Pair Color Code Chart: Number Color 1 White/Blue Stripe & Blue 2 White/Orange Stripe & Orange Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +75C Bulk Cable Weight: 31.252 Kg/Km Max. Recommended Pulling Tension: 57.827 N Min. Bend Radius/Minor Axis: 25.400 mm Min. Bend/Installation: 43.180 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP, UL444 CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes Page 1 of 3 09-11-2017Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1590A Multi-Conductor - Category 5e Nonbonded-Pair Cable EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Telecommunications Standards: 568-B.2 Category 5e Other Specification: NEMA WC-63.1 Category 5e, UL verified to Category 5e Flame Test UL Flame Test: NFPA 262 CSA Flame Test: FT4, FT6 Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 1588A, 1588R Electrical Characteristics (Overall) Nom. Mutual Capacitance: Capacitance (pF/m) 45.934 Maximum Capacitance Unbalance (pF/100 m): 330 Nominal Velocity of Propagation: VP (%) 72 Maximum Delay: Delay (ns/100 m) 538 100MHz Max. Delay Skew: Delay Skew (ns/100 m) 45 Maximum Conductor DC Resistance: DCR 20C (Ohm/100 m) 9.38 Max. Operating Voltage - UL: Voltage 300 V RMS Maximum DCR Unbalanced: DCR Unbalance 20C (%) 5 Electrical Characteristics-Premise (Overall) Premise Cable Electrical Table 1: Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. ACR (dB) Min. PSACR (dB) Min RL (dB) Min. SRL (dB) 1 2.0 65.3 62.3 63.0 60.3 20.0 23.0 4 4.1 56.3 53.3 51.0 49.2 23.0 23.0 8 5.8 51.8 48.8 46.0 43.0 24.5 24.5 10 6.5 50.3 47.3 43.0 40.8 25.0 25.0 16 8.2 47.3 44.3 39.0 36.0 25.0 25.0 20 9.3 45.8 42.8 36.5 33.5 25.0 25.0 25 10.4 44.3 41.3 33.9 30.9 24.3 24.3 31.25 11.7 42.9 39.9 31.0 28.2 23.6 23.6 62.5 17.0 38.4 35.4 22.0 19.0 21.5 21.5 100 22.0 35.3 32.3 14.0 10.3 20.1 20.1 155 28.1 32.5 29.5 4.4 1.4 15.8 200 32.0 30.8 27.8 4.0 1.0 15.0 Premise Cable Electrical Table 2: Freq. (MHz) Input (Unfitted) Imp. (Ohms) Fitted Impedance Min. ELFEXT (dB) Min. PSELFEXT (dB) 1 100 15 100 15 63.8 60.8 4 100 15 100 15 51.7 48.7 8 100 15 100 15 45.7 42.7 10 100 15 100 15 43.8 40.8 Page 2 of 3 09-11-2017