Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1883A Multi-Conductor - Single-Pair Cable For more Information please call 1-800-Belden1 General Description: 24 AWG stranded (7x32) TC conductors, polypropylene insulation, twisted pair, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: Pairs AWG Stranding Conductor Material Dia. (in.) 1 24 7x32 TC - Tinned Copper .024 Total Number of Conductors: 2 Insulation Insulation Material: Insulation Material Dia. (in.) PP - Polypropylene .040 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Coverage (%) Beldfoil Tape Aluminum Foil-Polyester Tape 100.000 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 24 7x32 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Overall Cable Overall Nominal Diameter: 0.121 in. Pair Pair Color Code Chart: Number Color 1 Black & Red Mechanical Characteristics (Overall) Operating Temperature Range: -30C To +60C Bulk Cable Weight: 10 lbs/1000 ft. Max. Recommended Pulling Tension: 16 lbs. Min. Bend Radius/Minor Axis: 1.250 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR CEC/C(UL) Specification: CMG EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: No EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes Page 1 of 3 08-26-2016Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1883A Multi-Conductor - Single-Pair Cable CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading CSA Flame Test: FT4 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 52 Nom. Inductance: Inductance (H/ft) .17 Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 31 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/ft) 58 Nominal Velocity of Propagation: VP (%) 66 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 23.5 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/1000 ft) 18.5 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2 Amps per conductor 25C Notes (Overall) Notes: The jacket and shield are bonded so both can be removed on automatic stripping equipment. Drain wire is inside foil shield. For cross-connect use with 1408R (et. al.) Snake Cables. Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 1883A N3UN1000 1,000 FT 14.000 LB GREEN, MIL 2 24 PP FS FRPVC 1883A N3UN2000 2,000 FT 24.000 LB GREEN, MIL 2 24 PP FS FRPVC 1883A N3UU1000 1,000 FT 12.000 LB GREEN, MIL 2 24 PP FS FRPVC 1883A N3U1000 1,000 FT 11.000 LB GREEN, MIL TRANSFER REVIEW (20 TO 30) 1883A 001N1000 1,000 FT 14.000 LB BROWN 2 24 PP FS FRPVC 1883A 001U1000 1,000 FT 12.000 LB BROWN 2 24 PP FS FRPVC 1883A 0011000 1,000 FT 11.000 LB BROWN 2 24 PP FS FRPVC 1883A 002N1000 1,000 FT 14.000 LB RED 2 24 PP FS FRPVC 1883A 002U1000 1,000 FT 12.000 LB RED 2 24 PP FS FRPVC 1883A 0021000 1,000 FT 11.000 LB RED 2 24 PP FS FRPVC 1883A 004N1000 1,000 FT 14.000 LB YELLOW 2 24 PP FS FRPVC 1883A 004N2000 2,000 FT 24.000 LB YELLOW 2 24 PP FS FRPVC 1883A 006N1000 1,000 FT 14.000 LB BLUE, LIGHT 2 24 PP FS FRPVC 1883A 006N2000 2,000 FT 26.000 LB BLUE, LIGHT 2 24 PP FS FRPVC 1883A 006U1000 1,000 FT 12.000 LB BLUE, LIGHT 2 24 PP FS FRPVC 1883A 0061000 1,000 FT 11.000 LB BLUE, LIGHT 2 24 PP FS FRPVC 1883A 007U1000 1,000 FT 12.000 LB VIOLET TRANSFER REVIEW (20 TO 30) 1883A 0071000 1,000 FT 11.000 LB VIOLET 2 24 PP FS FRPVC 1883A 008N1000 1,000 FT 14.000 LB GRAY 2 24 PP FS FRPVC Page 2 of 3 08-26-2016