Product: 2140A Category 6 Indoor/OSP/CM-LS F/UTP Cable Product Description CAT6 (250 MHz), 4 Pair, F/UTP-Foil Shielded, Indoor/Outdoor OSP/CM-LS, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, Polyolefin Insulation, Patented X-Spline, Gel-Filled, , Overall Beldfoil Shield with Drain Wire, Ripcord, UV-Resistant Flame Retardant Polyolefin Jacket Technical Specifications Product Overview OSP-Outdoor, Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Suitable Applications: Video, RS-422, 350MHz Category 6, Duct Patent: This product has one or more applicable patents. More information on patents can be found at . Min. Min. Min. Min. RL Min. Min. Frequency Max. Insertion Loss Min. ACRF Min. PSACRF Max./Min. Input Max./Min. Fitted NEXT PSNEXT PSACR (Return Loss) TCL ELTCTL MHz (Attenuation) (ELFEXT) dB (PSELFEXT) dB Impedance (unFitted) Impedance dB dB dB dB dB dB 1 2.0 dB/100m 74.3 72.3 70.3 67.8 64.8 20.0 100 15 Ohm 100 15 Ohm 40.0 35.0 4 3.8 dB/100m 65.3 63.3 59.5 55.7 52.7 23.0 100 15 Ohm 100 15 Ohm 40.0 23.0 8 5.3 dB/100m 60.8 58.8 53.4 49.7 46.7 24.5 100 15 Ohm 100 15 Ohm 40.0 16.9 10 6.0 dB/100m 59.3 57.3 51.4 47.8 44.8 25.0 100 15 Ohm 100 15 Ohm 40.0 15.0 16 7.6 dB/100m 56.3 54.3 46.7 43.7 40.7 25.0 100 15 Ohm 100 15 Ohm 38.0 10.9 20 8.5 dB/100m 54.8 52.8 44.3 41.7 38.7 25.0 100 15 Ohm 100 15 Ohm 37.0 9.0 25 9.5 dB/100m 53.3 51.3 41.8 39.8 36.8 24.3 100 15 Ohm 100 15 Ohm 36.0 7.0 31.25 10.7 dB/100m 51.9 49.9 39.2 37.9 34.9 23.6 100 15 Ohm 100 15 Ohm 35.1 5.1 62.5 15.4 dB/100m 47.4 45.4 30.0 31.8 28.8 21.5 100 15 Ohm 100 15 Ohm 32.0 100 19.8 dB/100m 44.3 42.3 22.5 27.8 24.8 20.1 100 15 Ohm 100 15 Ohm 30.0 155 25.2 dB/100m 41.5 39.5 14.3 23.9 20.9 18.8 100 22 Ohm 100 15 Ohm 28.1 200 29.0 dB/100m 39.8 37.8 8.8 21.7 18.7 18.0 100 22 Ohm 100 15 Ohm 27.0 250 32.8 dB/100m 38.3 36.3 3.5 19.8 16.8 17.3 100 32 Ohm 100 15 Ohm 26.0 Voltage UL Voltage Rating 300 V (CM) Mechanical Characteristics Temperature UL Temperature Operating Installation Storage 75C -40C To +75C -20C To +75C -40C To +75C Bend Radius Stationary Min. Installation Min. 3.0 in (76 mm) 3.75 in Max. Pull Tension: 25 lbs (11 kg) Bulk Cable Weight: 66 lbs/1000ft Standards and Compliance Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor, Non-Halogenated, Sunlight Resistance Flammability / Reaction to UL 1685 (UL Loading-Limited Smoke) Fire: NEC / UL Compliance: CM CEC / C(UL) Compliance: CM IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 Data Category: Category 6 TIA/EIA Compliance: ANSI/TIA-568.2-D Category 6 ISO/IEC Compliance: 11801 ed 2.2 (2011) Class E European Directive EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2017-07-10 Compliance: APAC Compliance: China RoHS II (GB/T 26572-2011) Other Standard Outdoor Use ANSI/ICEA S-56-434, Broadband Outdoor Use ANSI/ICEA S-99-689, Indoor/Outdoor Use ANSI/ICEA S-100-685, Verified Category 6 Compliance(s): Product Notes Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Notes: Markings from Max. Put-Up Length to 0. Not Suitable for Direct Burial. History Update and Revision: Revision Number: 0.220 Revision Date: 12-15-2021 Variants Item Color UPC 2140A 0101000 Black 612825400875