Product: 29502 VFD 300% Gnd, 3C+G 12 Str TC,XLPE Ins+PVC Gnd, OS+TC Brd w/ 12 TC Drain, Blk PVC Jkt, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC Product Description Belden 300% Ground Flexible VFD, 3 Conductor 12AWG (65x30) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil+Tinned Copper Braid(85%) Shield w/12AWG Tinned Copper Drain, Black PVC Outer Jacket, 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC 1000V CSA AWM I/II A/B 600V CIC TC SUN RES DIR BUR Oil Resistant Technical Specifications Product Overview Suitable Applications: Variable Frequency Drives (VFD) AC Motor and Drive Systems Construction Details Conductor Element Number of Element Size Stranding Material Conductor(s) 3 12 AWG 65x30 TC - Tinned Copper Ground 1 12 AWG 65x30 TC - Tinned Copper Insulation Element Material Nom. Thickness Color Code Conductor(s) XLPE - Cross-Linked Polyethylene (Thermoset) 0.046 in (1.2 mm) Black and Numbered Ground PVC - Polyvinyl Chloride 0.046 in (1.2 mm) Green/Yellow Stripe Outer Shield Shield Type Material Coverage Tape Tri-Laminate (Alum+Poly+Alum) 100% Braid Tinned Copper (TC) 85% Outer Jacket Material Nom. Thickness Nom. Diameter Ripcord PVC - Polyvinyl Chloride 0.073 in (1.9 mm) 0.630 in (16.0 mm) Yes Overall Cable Diameter (Nominal): 0.630 in (16.0 mm) Electrical Characteristics Electricals Nom. Capacitance Nom. Capacitance Cond-to-Other Nom. Characteristic Nom. Velocity of Element Nom. Conductor DCR Max. Current Cond-to-Cond (Conds + Shield) Impedence Prop. 1.566 Ohm/1000ft (5.138 30 Amps per Conductor at 30C Conductor(s) 26 pF/ft (85 pF/m) 47 pF/ft (150 pF/m) 71 Ohm 55% Ohm/km) (per NEC) Voltage UL Voltage Rating 1000 V (TC, WTTC, UL Flexible Motor Supply Cable, CSA AWM I/II A/B), 600 V (C(UL) CIC TC) Mechanical Characteristics TemperatureUL Temperature Operating 90C Dry, 90C Wet -40C To +90C Bend Radius Stationary Min. Installation Min. 7.6 in (190 mm) 7.6 in (190 mm) Max. Pull Tension: 458 lbs Bulk Cable Weight: 277 lbs/1000ft (412 kg/km) Standards and Compliance Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial Sustainability: CA Prop 65 Flammability / Reaction to Fire: UL1685 UL Loading, FT4, FT4, 1202, 383 Vertical Tray Flame Test (70,000 BTU) NEC / UL Compliance: Article 336, TC-ER, WTTC, RHW-2, UL Flexible Motor Supply Cable AWM Compliance: I/II A/B CEC / C(UL) Compliance: CIC, TC ICEA Compliance: S-95-658 European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) APAC Compliance: China RoHS II (GB/T 26572-2011) Other Standard Compliance(s): P-07-KA070003-MSHA History Update and Revision: Revision Number: 0.451 Revision Date: 12-15-2021 Variants Item Color Putup Type Length UPC 29502 010100 Black Reel 100 ft 612825136743 29502 010250 Black Reel 250 ft 612825136781 29502 010500 Black Reel 500 ft 612825136804 29502 0101000 Black Reel 1,000 ft 612825136750 29502 0105000 Black Reel 5,000 ft 612825136811 2022 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.