Product: 29510 VFD 300% Gnd, 3C+G 16 Str TC, XLPE Ins+PVC Gnd, OS+TC Brd, 1 Pr 16 Str TC XLPE IS, Blk PVC Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable Product Description Belden 300% Ground Flexible VFD, 3 Conductor 16AWG (26x30) Tinned Copper, XLPE Insulation M4 Color Code+PVC Insulated Ground, Overall Beldfoil+Tinned Copper Braid(85%) Shield, 1 Pair 16AWG (26x30) Tinned Copper XLPE Beldfoil, Black PVC Outer Jacket, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable 1000V CSA AWM I/II A/B 600V CIC TC SUN RES DIR BUR Oil Resistant Technical Specifications Product Overview Suitable Applications: Variable Frequency Drives (VFD) AC Motor and Drive Systems Construction Details Conductor Element Number of Element AWG Stranding Material Notes Conductor(s) 3 16 26x30 TC - Tinned Copper Pair(s) 1 16 26x30 TC - Tinned Copper Used as control or brake pair Ground 1 16 26x30 TC - Tinned Copper Insulation Element Material Thickness in. Color Code Conductor(s) XLPE - Cross-Linked Polyethylene (Thermoset) 0.046 Black and Numbered Pair(s) XLPE - Cross-Linked Polyethylene (Thermoset) 0.032 Black, White Ground PVC - Polyvinyl Chloride 0.047 Green/Yellow Stripe Inner Shield Material Element Shield Type Material Coverage Drainwire Type Notes Pair(s) Tape Bi-Laminate (Aulm/Poly) 1% 18 AWG (19x30) TC Foil-In, Shorting fold Outer Shield Material Shield Type Material Coverage Tape + Braid Tri-Laminate (Alum+Poly+Alum) + Tinned Copper (TC) 100% + 85% Table Notes: Foil+braid shield on power conductors & Ground only extra pair has own foil shield. Outer Jacket Material Material Thickness Nom. Diameter Ripcord PVC - Polyvinyl Chloride 0.075 in 0.750 in Yes Cable Diameter (Nominal): 0.750 in Electrical Characteristics Electricals Nom. Capacitance Nom. Nom. Inner Nom. Capacitance Nom. Capacitance Characteristic Nom. Velocity Element Cond-to-Other (Conds + Max. Current Conductor DCR Shield DCR Cond-to-Cond Cond-to-Shield Impedence of Prop. Shield) 0.079 18 Amps per Conductor Conductor(s) 46 pF/ft 38 pF/ft 83 pF/ft 37 Ohm 0.55% Ohm/1000ft at 30C (per NEC) Pair(s) 4 Ohm/1000ft 4.99 Ohm/1000ft 34 pF/ftGround Voltage UL Voltage Rating 600 V (TC, C(UL) TC), 1000 V (UL Flexible Motor Supply Cable, CSA AWM I/II A/B) Mechanical Characteristics Temperature UL Rating Operating 90C Dry, 90C Wet -40C To +90C Bend Radius Stationary Min. Installation Min. 7.5 in 9 in Max. Pull Tension: 336 lbs Bulk Cable Weight: 259 lbs/1000ft Standards and Compliance Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial Sustainability: CA Prop 65 Flammability / Fire Resistance: UL1685 UL Loading, FT4, FT4, 1202, 383 Vertical Tray Flame Test (70,000 BTU) NEC / UL Compliance: Article 336, TC-ER, UL Flexible Motor Supply Cable AWM Compliance: I/II A/B CEC / C(UL) Compliance: CIC, TC ICEA Compliance: S-95-658 European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE) APAC Compliance: China RoHS II (GB/T 26572-2011) Other Standard Compliance(s): P-07-KA070003 History Update and Revision: Revision Number: 0.378 Revision Date: 07-30-2020 2020 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.