Product: 3073F DataTray 100 Twinax, 1 Pr 18 Str TC, PP Ins, OS+TC Brd, PVC Jkt, TC, PLTC, ITC, CMG Product Description Twinax 100, 1 Pair 18 AWG (7x26) Tinned Copper, PP Insulation, Overall Beldfoil+Tinned Copper Braid(55%) Shield, PVC Outer Jacket, TC, PLTC, ITC, CMG Technical Specifications Product Overview Suitable Applications: harsh environment, IIoT, factory or process automation, video, audio, data communication, etc. Construction Details Conductor AWG Stranding Nom. Diameter Material 18 7x26 0.046 in TC - Tinned Copper Insulation Material Color Code Nom. Diameter Notes PP - Polypropylene White & Blue 0.128 Flame Retardant Outer Shield Material Layer Outer Shield Type Material Material Trade Name Coverage Notes 1 Tape Bi-Laminate (Alum+Poly) Beldfoil 100% Foil Out 2 Braid Tinned Copper (TC) 55% Outer Jacket Material Material Nom. Diameter PVC - Polyvinyl Chloride 0.388 in Electrical Characteristics Attenuation Frequency Nom. Attenuation dB/100ft 2 MHz 0.41 dB/100ft 10 MHz 1.33 dB/100ft 50 MHz 2.97 dB/100ft 100 MHz 4.20 dB/100ft 200 MHz 5.95 dB/100ft 400 MHz 7.52 dB/100ft Electricals Element Nom. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance Cond-to-Cond (Mutual) Nom. Impedence Nom. Velocity Pair(s) 6.9 Ohm/1000ft 2.9 Ohm/1000ft 15.3 pF/ft 100 Ohm 64.5% Voltage UL Voltage Rating 600 V (TC), 300 V (CMG, PLTC)Mechanical Characteristics Temperature UL Rating Operating 75C Dry, PLTC 75C Dry/Wet -40C to +75C Bend Radius Installation Min. 2.4 in Bulk Cable Weight: 61 lbs/1000ft Max. Pull Tension: 90 lbs Standards and Compliance Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, UV Resistance Sustainability: CA Prop 65 Flammability / Fire Resistance: UL1685 UL Loading, FT1, FT4, FT1, FT4 NEC / UL Compliance: Article 336, Article 725, Article 727, Article 800, CMG, ITC, PLTC, TC CEC / C(UL) Compliance: CMG European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE) APAC Compliance: China RoHS II (GB/T 26572-2011) Product Notes Notes: Cable contains rod fillers for better electrical performance. CPE Jacket Optional. History Update and Revision: Revision Number: 0.326 Revision Date: 07-31-2020 2020 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.