Product: 3079A Profibus, 1 Pr 22 Sol BC, PE Ins, OS+TC Brd, PVC Jkt, PLTC CMG Profibus DP Product Description Profibus, 1 Pair 22AWG (Solid) Bare Copper, PE Insulation, Overall Beldfoil+Tinned Copper Braid(65%) Shield, PVC Outer Jacket, PLTC CMG AWM 20201 SUN RES Profibus DP Technical Specifications harsh environment, outdoors, data transmission applications such as Profibus DP or PA, Instrumentation and computer cable, etc. exposure to temperature extremes, Suitable Applications: humidity/moisture, dust, and oil. Conductor Element Number of Element AWG Stranding Material Pair(s) 1 22 Solid BC - Bare Copper Insulation Element Material Thickness in. Color Code Notes Pair(s) PE - Polyethylene (Foam) 0.035 Red & Green Flame Retardant, Foam w/ skin Outer Shield Material Shield Type Material Coverage Tape + Braid Bi-Laminate (Alum+Poly) + Tinned Copper (TC) 65% + 65% Outer Jacket Material Material Thickness Nom. Diameter PVC - Polyvinyl Chloride 0.043 in 0.315 in Cable Diameter (Nominal): 0.315 in Electricals Element Nom. Conductor DCR Characteristic Impedence Max. Current Pair(s) 16 Ohm/1000ft 150 Ohm 2.3 Amps per Conductor Nom Outer Shield DCR: 3.9 Ohm/1000ft High Frequency (Nominal/Typical) Element Frequency MHz Nom. Insertion Loss Pair(s) 0.2 MHz 0.27 dB/100ft 4 MHz 0.67 dB/100ft 16 MHz 1.37 dB/100ft High Freq Frequency MHz Max. Insertion Loss (Attenuation) 0.2 MHz 1.1 dB/100m 4 MHz 2.65 dB/100m 16 MHz 5.4 dB/100m Voltage UL Voltage Rating 300 V (CMG, PLTC), 600 V (UL AWM 20201) TemperatureUL Rating Operating 75C (UL AWM 20201) -30C to +75C Bend Radius Stationary Min. Installation Min. 3.2 in 2.4 in Max. Pull Tension: 50 lbs Bulk Cable Weight: 52 lbs/1000ft Environmental Suitability: Indoor, Sunlight Resistance Flammability / Fire UL1685 FT4 Loading, FT4, 1202, IEC 60332-1-2 Resistance: NEC / UL Compliance: Article 725, Article 800, CMG, PLTC AWM Compliance: 20201 CEC / C(UL) Compliance: CMG CPR Euroclass: Eca European Directive EU CE Mark, EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE) Compliance: Notes: Siemens Sinec L2 Cable. For CPE jacketed version order Part No. YR45047. For LSZH (FRNC) jacketed version, order Part No. 3079T or YR44731. Update and Revision: Revision Number: 0.357 Revision Date: 08-25-2020 2020 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.