Product: 3082A DeviceBus, 2 Pr 15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, CMG PLTC-ER Product Description DeviceBus for ODVA DeviceNet, 2 Pair 15+18AWG (19x27+19x30) Tinned Copper, PVC+Foam PE Insulation, Individual Beldfoil & OA Tinned Copper Braid(65%) Shield, PVC Outer Jacket, CMG PLTC-ER Technical Specifications harsh environment, ODVA device-level communication, used with CIP (common Industrial Protocol) for control, configuration, and data collection between devices, such as sensors Suitable Applications: and actuators, and higher level devices such as PLC, and PC in industrial automation, bus topology, etc. Conductor Element Number of Element AWG Stranding Material Power Pair(s) 1 15 19x27 TC - Tinned Copper Data Pair(s) 1 18 TC - Tinned Copper Insulation Element Material Thickness in. Color Code Notes Power Pair(s) PVC - Polyvinyl Chloride 0.021 Red & Black Data Pair(s) PE - Polyethylene (Foam) 0.053 Blue & White HDPE Inner Shield Material Element Shield Type Material Coverage Power Pair(s) Tape Bi-Laminate (Alum+Poly) 100% Data Pair(s) Tape Bi-Laminate (Alum+Poly) 100% Outer Shield Material Shield Type Material Coverage Drainwire Type Braid Tinned Copper (TC) 65% 18 AWG (19x30) TC Outer Jacket Material Material Thickness Nom. Diameter PVC - Polyvinyl Chloride 0.060 in 0.480 in Cable Diameter 0.480 in (Nominal): Electricals Element Nom. Conductor DCR Nom. Capacitance Cond-to-Cond Characteristic Impedence Max. Current Power Pair(s) 3.6 Ohm/1000ft 8 Amps per Conductor Data Pair(s) 6.9 Ohm/1000ft 12 pF/ft 120 Ohm 5 Amps per Conductor Nom Outer Shield DCR: 1.8 Ohm/1000ft High Freq Element Frequency MHz Max. Insertion Loss (Attenuation) Max./Min. Input Impedance (unFitted) Data Pair(s) 0.125 MHz 0.13 dB/100ft 120 Ohm 0.5 MHz 0.25 dB/100ft 1 MHz 0.36 dB/100ft Voltage UL Voltage Rating300 V (CMG, PLTC-ER), 600 V (UL AWM 20201) Temperature UL Rating Operating 75C -20C to +75C Bend Radius Stationary Min. Installation Min. 4.8 in 4.8 in Max. Pull Tension: 190 lbs Bulk Cable Weight: 108 lbs/1000ft Environmental Suitability: Indoor, Sunlight Resistance, Oil Resistance Flammability / Fire UL1685 FT4 Loading, FT4, 1202, IEC 60332-1-2 Resistance: NEC / UL Compliance: Article 725, Article 800, CMG, PLTC-ER AWM Compliance: 20201, I/II A CEC / C(UL) CMG Compliance: CPR Euroclass: Eca European Directive EU CE Mark, EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE) Compliance: APAC Compliance: China RoHS II (GB/T 26572-2011) Other Standard ODVA Class 2 Thick Compliance(s): Thick. Meter marks on jacket to aid users in installation. ODVA DeviceNet is an Open DeviceNet Vendor Associatio, Inc. Trademark. Jacket printed 1PR16 instead of 1PR15 Notes: due to UL requirements for CMG Listing. Update and Revision: Revision Number: 0.385 Revision Date: 08-25-2020 2020 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.