Product: 49615A D-Subminiature Assembly, 5 ft, (25) 24 AWG (7x32) TC, S-R PVC/PVC, Foil+TC Braid Shld, CM Product Description Twenty-five 24 AWG stranded (7x32) tinned copper conductors, S-R PVC insulation, Beldfoil plus tinned copper braid shield, PVC jacket, five foot length. Technical Specifications Physical Characteristics (Overall) Conductor AWG Stranding Material Nominal Diameter No. of Conductors 24 7x32 TC - Tinned Copper 0.024 in 25 Conductor Count: 25 Insulation Material Nominal Wall Thickness SR-PVC - Polyvinyl Chloride (Semi-Rigid) 0.01 in Outer Shield Type Layer Material Material Trade Name Coverage % Tape 1 Bi-Laminate (Alum+Poly) Beldfoil 100% Braid 2 Tinned Copper (TC) 65% Outer Jacket Material Nominal Diameter Nominal Wall Thickness PVC - Polyvinyl Chloride 0.37 in 0.04 in Electrical Characteristics Voltage UL Voltage Rating 300 V RMS (UL AWM Style 2464) Temperature Range UL Temp Rating: 80C (UL AWM Style 2464) Standards NEC/(UL) Compliance: CM (cable only) UL AWM Style UL Style 2464 (300 V 80C) (cable only) Compliance: Applicable Environmental and Other Programs EU Directive Compliance: EU Directive 2003/11/EC (BFR) MII Order 39 (China Yes RoHS): Flammability, LS0H, Toxicity Testing UL voltage rating: 300 V RMS (UL AWM Style 2464)Plenum/Non-Plenum Plenum (Y/N): No Part Number Variants Item Color Length UPC 49615A 060S2 Chrome 5 ft 612825154105 Product Notes Molded handles are 100% shielded to guard against EMI/RFI. All connectors tin-plated and male connectors have detents for a positive shield to ground connection. Wiring is Notes: point-to-point with the shield to connector shell. History Update and Revision: Revision Number: 0.336 Revision Date: 12-15-2021 2022 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.