Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 5200UE Multi-Conductor - Commercial Audio Systems - 2 Conductors Cabled For more Information please call 1-800-Belden1 General Description: Security & Commercial Audio Cable, Riser-CMR, 2-16 AWG stranded bare copper conductors with polyolefin insulation, PVC jacket with ripcord Usage (Overall) Suitable Applications: Data Circuits, Monitor/Detection, Control Circuits, Initiating Circuits, Notification Circuits Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material 2 16 19x29 BC - Bare Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Material Wall Thickness (in.) PP - Polypropylene 0.008 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVC - Polyvinyl Chloride 0.017 Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Lay Length & Direction: Length (in.) Direction Twists (twist/ft) 4.000 Left Hand 3.000 Overall Cabling Color Code Chart: Number Color 1 Black 2 Red Overall Nominal Diameter: 0.180 in. Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +75C UL Temperature Rating: 75C Bulk Cable Weight: 23 lbs/1000 ft. Max. Recommended Pulling Tension: 59 lbs. Min. Bend Radius/Minor Axis: 1.750 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR NEC Articles: 800 CEC/C(UL) Specification: CMG EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes Page 1 of 3 01-05-2017Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 5200UE Multi-Conductor - Commercial Audio Systems - 2 Conductors Cabled EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Flame Test UL Flame Test: UL1666 Vertical Riser C(UL) Flame Test: FT4 Suitability Suitability - Indoor: Yes Plenum/Non-Plenum Plenum Number: 6200UE Surface Printing (Overall) Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/ft) 0.140 Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 23.000 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 4.2 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Description Current 10C Temperature Rise 6.25 Amps per conductor 25C ambient Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 5200UE 001U1000 1,000 FT 25.000 LB BROWN 2 16 PP FRPVC 5200UE 0011000 1,000 FT 26.000 LB BROWN 2 16 PO FRPVC 5200UE 0021000 1,000 FT 26.000 LB RED C 2 16 PP FRPVC 5200UE 0031000 1,000 FT 26.000 LB ORANGE 2 16 PP FRPVC 5200UE 0041000 1,000 FT 26.000 LB YELLOW 2 16 PP FRPVC 5200UE 0051000 1,000 FT 26.000 LB GREEN, DARK 2 16 PP FRPVC 5200UE 0061000 1,000 FT 26.000 LB BLUE, LIGHT 2 16 PP FRPVC 5200UE 0071000 1,000 FT 26.000 LB VIOLET 2 16 PP FRPVC 5200UE 008U1000 1,000 FT 25.000 LB GRAY 2 16 PP FRPVC 5200UE 008U500 500 FT 13.000 LB GRAY 2 16 PP FRPVC 5200UE 0081000 1,000 FT 26.000 LB GRAY C 2 16 PP FRPVC 5200UE 008500 500 FT 13.000 LB GRAY 2 16 PP FRPVC 5200UE 009U1000 1,000 FT 25.000 LB WHITE 2 16 PP FRPVC 5200UE 0091000 1,000 FT 26.000 LB WHITE 2 16 PP FRPVC 5200UE 010U1000 1,000 FT 25.000 LB BLACK 2 16 PP FRPVC 5200UE 0101000 1,000 FT 26.000 LB BLACK 2 16 PP FRPVC Notes: C = CRATE REEL PUT-UP. Revision Number: 3 Revision Date: 08-08-2013 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether Page 2 of 3 01-05-2017