Product: 5220UJ Fire Alarm, 16-2c BC, FPL Product Description Fire Alarm Cable, Rated-FPL, 2-16 AWG solid bare copper conductors with foam polyolefin insulation, PVC jacket with ripcord Technical Specifications Product Overview Suitable Applications: Fire Alarm, Addressable Systems, Circuits: Audio, Control, Initiating, Notification Physical Characteristics (Overall) Conductor AWG Stranding Material No. of Conductors 16 Solid BC - Bare Copper 2 Conductor Count: 2 Insulation Material Material Trade Name Nominal Wall Thickness PE - Polyethylene (Foam) Datalene 0.015 in Color Chart Color Black Red Outer Shield Material Material No Shield Outer Jacket Material Material Nominal Diameter Nominal Wall Thickness Ripcord PVC - Polyvinyl Chloride 0.23 in 0.033 in Yes Construction and Dimensions Cabling Twists 4.8 twist/ft Electrical Characteristics Conductor DCR Nominal Conductor DCR 3.9 Ohm/1000ft Capacitance Nom. Capacitance Conductor to Conductor 13 pF/ftInductance Nominal Inductance 0.17 H/ft Current Max. Recommended Current A 6.3 Amps per Conductor at 25C Voltage UL Voltage Rating 300 V RMS Temperature Range UL Temp Rating: 75C Operating Temp Range: -20C To +75C Mechanical Characteristics Bulk Cable Weight: 28.6 lbs/1000ft Max. Pull Tension: 62.4 lbs Min Bend Radius/Minor Axis: 2.25 in Standards NEC Articles: Article 760 NEC/(UL) Compliance: FPL Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/96/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-01 MII Order 39 (China RoHS): Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1685 UL Loading UL voltage rating: 300 V RMS Plenum/Non-Plenum Plenum (Y/N): No Plenum Number: 6220UJ Part Number Variants Item Color UPC 5220UJ 0021000 Red 612825158363 Footnote: C - CRATE REEL PUT-UP. History Update and Revision: Revision Number: 0.227 Revision Date: 06-24-2020 2020 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and