Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5400F1 Multi-Conductor - Water-Blocked for Use in Underground Ducts - 2 Cond Cabled For more Information please call 1-800-Belden1 General Description: Security & Alarm Cable, Rated-CM, 2-20 AWG stranded tinned copper conductors with PVC insulation, waterblocking tape, Beldfoil shield and PVC jacket with ripcord Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material 2 20 7x28 TC - Tinned Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PVC - Polyvinyl Chloride 0.254 Outer Shield Outer Shield Material: Outer Shield Trade Name Outer Shield Material Beldfoil Aluminum Foil-Polyester Tape Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 24 solid TC - Tinned Copper Outer Shield Waterblocking Tape: Non-woven waterblocking tape Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.635 Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Lay Length & Direction: Length (mm) 50.7998 Overall Nominal Diameter: 5.232 mm Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +105C Bulk Cable Weight: 28.276 Kg/Km Max. Recommended Pulling Tension: 165.028 N Min. Bend Radius/Minor Axis: 50.800 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM CEC/C(UL) Specification: CM EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005 EU Directive 2002/96/EC (WEEE): Yes Page 1 of 2 09-11-2017Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5400F1 Multi-Conductor - Water-Blocked for Use in Underground Ducts - 2 Cond Cabled EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading CSA Flame Test: FT1 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/m) 0.55777 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 183.736 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 331.381 Nom. Conductor DC Resistance: DCR 20C (Ohm/km) 33.7943 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/km) 58.730 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 3.75 Amps per conductor 25C (10C rise in temp) Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 5400F1 0081000 1,000 FT 22.000 LB GRAY C 2 20 S-R PVC FS PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 09-12-2013 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributors inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Beldens knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 2 of 2 09-11-2017