Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 5500UG Multi-Conductor - Residential, Light Commercial and Institutional Applications For more Information please call 1-800-Belden1 General Description: Security & Alarm Cable, Rated-CM, 2-22 AWG stranded bare copper conductors with polyolefin insulation, PVC jacket Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material 2 22 7x30 BC - Bare Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Material Wall Thickness (in.) PP - Polypropylene .006 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVC - Polyvinyl Chloride .015 Overall Cable Overall Cabling Color Code Chart: Color Black Red Overall Nominal Diameter: 0.114 in. Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +75C UL Temperature Rating: 75C Bulk Cable Weight: 7.300 lbs/1000 ft. Max. Recommended Pulling Tension: 18.200 lbs. Min. Bend Radius/Minor Axis: 1.200 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM NEC Articles: 800 CEC/C(UL) Specification: CM EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes Page 1 of 2 09-11-2017Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 5500UG Multi-Conductor - Residential, Light Commercial and Institutional Applications CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading CSA Flame Test: FT1 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/ft) .155 Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 20 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 16.1 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2.8 Amps per conductor 25C Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 5500UG U4FC1000 1,000 FT 7.000 LB BEIGE U4F 2 22 PP FRPVC 5500UG U4FU500 500 FT 4.500 LB BEIGE U4F 2 22 PP FRPVC 5500UG 001C1000 1,000 FT 7.000 LB BROWN 2 22 PP FRPVC 5500UG 001C500 500 FT 3.500 LB BROWN 2 22 PP FRPVC 5500UG 003C500 500 FT 3.500 LB ORANGE 2 22 PP FRPVC 5500UG 003U500 500 FT 4.500 LB ORANGE 2 22 PP FRPVC 5500UG 004C1000 1,000 FT 7.000 LB YELLOW 2 22 PP FRPVC 5500UG 004C500 500 FT 3.500 LB YELLOW 2 22 PP FRPVC 5500UG 004U500 500 FT 4.500 LB YELLOW 2 22 PP FRPVC 5500UG 005C1000 1,000 FT 7.000 LB GREEN, DARK 2 22 PP FRPVC 5500UG 005C500 500 FT 3.500 LB GREEN, DARK 2 22 PP FRPVC 5500UG 005U500 500 FT 4.500 LB GREEN, DARK 2 22 PP FRPVC 5500UG 006C500 500 FT 3.500 LB BLUE, LIGHT 2 22 PP FRPVC 5500UG 006U500 500 FT 4.500 LB BLUE, LIGHT 2 22 PP FRPVC 5500UG 007C1000 1,000 FT 7.000 LB VIOLET 2 22 PP FRPVC 5500UG 007C500 500 FT 3.500 LB VIOLET 2 22 PP FRPVC 5500UG 007U500 500 FT 4.500 LB VIOLET 2 22 PP FRPVC 5500UG 008C1000 1,000 FT 7.000 LB GRAY 2 22 PP FRPVC 5500UG 008C500 500 FT 3.500 LB GRAY 2 22 PP FRPVC 5500UG 008U1000 1,000 FT 8.000 LB GRAY 2 22 PP FRPVC 5500UG 009C1000 1,000 FT 7.000 LB WHITE 2 22 PP FRPVC 5500UG 009C500 500 FT 3.500 LB WHITE 2 22 PP FRPVC 5500UG 009U1000 1,000 FT 8.000 LB WHITE 2 22 PP FRPVC Revision Number: 1 Revision Date: 03-11-2013 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributors inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Beldens knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 2 of 2 09-11-2017