Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 6020FL Multi-Conductor - Commercial Applications - 2 Conductors Cabled For more Information please call 1-800-Belden1 General Description: Fire Alarm Cable, Plenum-FPLP, 2-12 AWG solid bare copper conductors with Flamarrest insulation, Overall Beldfoil shield, Flamarrest jacket with ripcord Usage (Overall) Suitable Applications: Fire Protection, Alarm, Signal, Monitor/Detection, Audio Circuits, Control Circuits, Initiating Circuits, Notification Circuits Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material 2 12 Solid BC - Bare Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Trade Name Insulation Material Wall Thickness (in.) Flamarrest LS PVC - Low Smoke Polyvinyl Chloride 0.011 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Coverage (%) Beldfoil Tape Aluminum Foil-Polyester Tape w/Shorting Fold 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 20 solid TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Nom. Wall Thickness (in.) Flamarrest LS PVC - Low Smoke Polyvinyl Chloride .015 Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Color Code Chart: Number Color 1 Black 2 Red Overall Nominal Diameter: 0.243 in. Mechanical Characteristics (Overall) Operating Temperature Range: 0C To +75C UL Temperature Rating: 75C Bulk Cable Weight: 57.200 lbs/1000 ft. Max. Recommended Pulling Tension: 172 lbs. Min. Bend Radius/Minor Axis: 2.500 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: FPLP NEC Articles: 760 EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes Page 1 of 2 09-11-2017Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 6020FL Multi-Conductor - Commercial Applications - 2 Conductors Cabled EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Other Specification: California State Fire Marshall Flame Test UL Flame Test: NFPA 262 Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 5020FL Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/ft) .14 Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 101 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/ft) 182 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 1.53 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/1000 ft) 7.2 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 12 Amps per conductor 25C Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 6020FL 0021000 1,000 FT 61.000 LB RED C 2 12 FLRST FS FLRST Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 03-13-2013 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributors inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Beldens knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 2 of 2 09-11-2017