Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 6541FE Multi-Conductor - Commercial Applications For more Information please call 1-800-Belden1 General Description: Security & Alarm Cable, Plenum-CMP, 2-22 AWG stranded bare copper pairs with Flamarrest insulation, Beldfoil shield and Flamarrest jacket with ripcord Usage (Overall) Suitable Applications: Security Systems, Intercom/PA Systems, Sound/Audio Systems, Power Limited Controls Physical Characteristics (Overall) Conductor AWG: Pairs AWG Stranding Conductor Material 2 22 7x30 BC - Bare Copper Total Number of Conductors: 4 Insulation Insulation Material: Insulation Trade Name Insulation Material Wall Thickness (in.) Flamarrest LS PVC - Low Smoke Polyvinyl Chloride 0.009 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Coverage (%) Beldfoil Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 24 (7x32) TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Nom. Wall Thickness (in.) Flamarrest LS PVC - Low Smoke Polyvinyl Chloride .015 Outer Jacket Ripcord: Yes Overall Cable Overall Nominal Diameter: 0.203 in. Pair Pair Color Code Chart: Number Color 1 Black & Red 2 Black & White Mechanical Characteristics (Overall) Operating Temperature Range: 0C To +75C UL Temperature Rating: 75C Bulk Cable Weight: 20.700 lbs/1000 ft. Max. Recommended Pulling Tension: 41.900 lbs. Min. Bend Radius/Minor Axis: 2 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP NEC Articles: 800 CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes Page 1 of 3 09-11-2017Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 6541FE Multi-Conductor - Commercial Applications EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Flame Test UL Flame Test: NFPA 262 C(UL) Flame Test: FT6 Suitability Suitability - Indoor: Yes Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 5541FE Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/ft) .18 Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 33 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/ft) 59.4 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 16.3 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/1000 ft) 13.9 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2.2 Amps per conductor 25C (10C rise in temp) Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 6541FE 877U1000 1,000 FT 22.000 LB NATURAL 2 PR 22 FLRST FS FLRST 6541FE 877U500 500 FT 11.500 LB NATURAL 2 PR 22 FLRST FS FLRST 6541FE 8771000 1,000 FT 23.000 LB NATURAL C 2 PR 22 FLRST FS FLRST Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 01-20-2015 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributors inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Beldens knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 2 of 3 09-11-2017