Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 73404W Multi-Conductor - 600V Unshielded, Light to Moderate Flexing Applications Up to 1 Million Flex Life Cycles For more Information please call 1-800-Belden1 General Description: 14 AWG stranded (41x30) bare copper conductors, PVC insulation, oil-resistant PVC jacket. Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material 3 14 41x30 BC - Bare Copper Total Number of Conductors: 4 Ground Wire Ground Wire (Y/N): Y Ground Wire AWG: 14 Ground Wire Stranding: 41x30 Ground Wire Conductor Material: BC - Bare Copper Ground Wire Insulation Material: PVC - Polyvinyl Chloride Insulation Insulation Material: Insulation Material Wall Thickness (mm) PVC - Polyvinyl Chloride 0.559 Insulation Color Code Chart: Color Description Black Individually Numbered Yellow/Green Ground Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 1.397 Overall Cable Overall Nominal Diameter: 10.262 mm Mechanical Characteristics (Overall) Storage Temperature Range: -40C To +90C Installation Temperature Range: Flexing: -5C To +90C Bulk Cable Weight: 315.498 Kg/Km Max. Recommended Pulling Tension: 573.818 N Min. Bend Radius/Minor Axis: 50.800 mm Min. Bend/Installation: 50.800 mm Min. Bend Radius (Continuous Flexing): 50.800 mm Flex Cycle Rating: 1 Million Flexes Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs AWM Specification: UL Style 2587 (600 V 90C) CSA Specification: 600 V AWM I/II A/B EU Directive 2011/65/EU (ROHS II): Yes MII Order 39 (China RoHS): Yes Other Specification: VDE 0472, Section 803 Oil Test, EU Low Voltage Directive 2014/35/EC, EU Directive 2011/65/EU(RoHS2), REACH Regulation (EC 1907/2006), California Proposition 65 Page 1 of 2 10-02-2017Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 73404W Multi-Conductor - 600V Unshielded, Light to Moderate Flexing Applications Up to 1 Million Flex Life Cycles Flame Test CSA Flame Test: FT1 Suitability Suitability - Burial: Yes Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/m) 0.558 Max. Capacitance Conductor to Conductor: Freq. (MHz) Capacitance (pF/m) 0.001 118.116 Nom. Conductor DC Resistance: DCR 20C (Ohm/km) 8.531 Max. Operating Voltage - UL: Voltage 600V Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 73404W 008100 100 FT 27.500 LB GRAY 14AWG 41/30 4C UNSHIELDED 73404W 0081000 1,000 FT 224.000 LB GRAY 14AWG 41/30 4C UNSHIELDED 73404W 008500 500 FT 115.000 LB GRAY 14AWG 41/30 4C UNSHIELDED Revision Number: 0 Revision Date: 09-27-2017 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Page 2 of 2 10-02-2017