74010PU 1 Networking Cables 2 Datatwist cable FOR PROFINET TYPE A 3 CAT 6A S/FTP 4 2017-05-11 v1 5 Applications Horizontal and building backbone cable Support current and future Category 6a, 7 applications, such as: 10GBase-T (10 Gigabit Ethernet), 1000Base-T (Gigabit Ethernet), 100 Base-T, 10 Base-T, FDDI, ATM PROFINET4 Pairs. General standards International standard: ISO/IEC 11801 2nd edition (2002) and ISO/IEC 11801 Amendment 2 (2010) European standard: EN 50173-1 (2002) and EN 50173-1 Amendment 1 (2009) AWM 21292 Construction & Dimensions 1. Conductor Material Solid bare copper ETP Diameter AWG 22 2. Insulation Material Foamed polyethylene Nominal diameter over insulation 1.54 mm 3. Cable core Pair 2 twisted insulated conductors with overall foil Foil Laminated aluminium-polyester Aluminium facing outside Number of shielded pairs 4, all twisted together Colour code pair 1 White / Blue Colour code pair 2 White / Orange Colour code pair 3 White / Green Colour code pair 4 White / Brown 4. Braid Material Solid tinned copper Coverage 80% 5. Jacket Material PUR Diameter 8.7 0.3 mm Colour GREEN (similar RAL6018) Electrical characteristics Reference standard : ISO/IEC 61156-5 edition 2.0 (2009) Low frequency and D.C. (at 20C) Specification Unit /100m D.C. resistance conductor < 5.91 Resistance unbalance: within a pair / between pairs < 2 / < 4 % Insulation resistance 5000 M.km Dielectric strength conductor-conductor and conductor-screen (2 sec.) 2.5 kV DC Mutual capacitance < 56 nF/km Capacitance unbalance pair to ground < 1600 pF/km Nominal velocity of propagation (for information only) 0.73 c Delay skew (differential delay) 25 ns/100m Transfer impedance according IEC 61156-5 Grade 1 Coupling attenuation according IEC 61156-5 Type I High frequency (at 20) TYPE 1* 4 10 16 31.2 62.5 100 125 200 250 300 600 MHz Attenuation 2.0 3.7 5.9 7.4 10.4 14.9 19.0 21.4 27.5 31.0 34.2 50.1 dB/100m NEXT 78.0 78.0 78.0 78.0 78.0 75.5 72.4 70.9 67.9 66.4 65.2 60.7 dB/100m PS NEXT dB/100m 75.0 75.0 75.0 75.0 75.0 72.5 69.4 67.9 64.9 63.4 62.2 57.7 ACR 76.0 74.3 72.1 70.6 67.6 60.6 53.4 49.6 40.4 35.5 31.1 10.6 dB/100m PS ACR 73.0 71.3 69.1 67.6 64.6 57.6 50.4 46.6 37.4 32.5 28.1 7.6 dB/100m ACR-F 78.0 78.0 75.3 71.2 65.4 59.4 55.3 53.4 49.3 47.3 45.8 39.7 dB/100m PS ACR-F 75.0 75.0 72.3 68.2 62.4 56.4 52.3 50.4 46.3 44.3 42.8 36.7 dB/100m Return Loss 20.0 23.0 25.0 25.0 23.6 21.5 20.1 19.4 18.0 17.3 17.3 17.3 dB/100m TCL level 1 dB/100m 40.0 34.0 30.0 28.0 25.1 22.0 20.0 19.0 17.0 16.0 EL TCTL 35.0 23.0 15.0 10.9 5.1 dB/100m Impedance 122.2 115.2 111.9 111.9 114.1 118.3 121.9 123.9 128.8 131.5 131.6 131.6 upper limit Impedance 81.8 86.8 89.4 89.4 87.7 84.5 82.0 80.7 77.6 76.0 76.0 76.0 lower limit Propagation 570 552 545 543 540 539 538 537 536 536 536 535 ns/100m delay NOTE: Limits below 4MHz are for information only 2