74011NH 1 Networking Cables 2 Datatwist cable FOR PROFINET TYPE B 3 CAT 6A S/FTP 4 2017-05-11 v1 5 Applications Horizontal and building backbone cable Support current and future Category 6A,applications, such as: 10GBase-T (10 Gigabit Ethernet), 1000Base-T (Gigabit Ethernet), 100 Base-T, 10 Base-T, FDDI, ATM General standards International standard: ISO/IEC 11801 2nd edition (2002) and ISO/IEC 11801 Amendment 2 (2010) European standard: EN 50173-1 (2002) and EN 50173-1 Amendment 1 (2009) AWM 20851 Construction & Dimensions 1. Conductor Material Stranded bare copper Diameter AWG 23/7 (7x0.22) 2. Insulation Material Foamed polyethylene Nominal diameter over insulation 1.58 mm 3. Cable core Pair 2 twisted insulated conductors with overall foil Foil Laminated aluminium-polyester Aluminium facing outside Number of shielded pairs 4, all twisted together Colour code pair 1 White / Blue Colour code pair 2 White / Orange Colour code pair 3 White / Green Colour code pair 4 White / Brown 4. Braid Material Solid tinned copper Coverage 85% 5. Jacket Material LSZH Diameter 8.7 0.3 mm Colour Green (similar RAL6018) Electrical characteristics Reference standard : ISO/IEC 61156-5 edition 2.0 (2009) Low frequency and D.C. (at 20C) Specification Unit /100m D.C. resistance conductor < 7.19 Resistance unbalance: within a pair / between pairs < 2 / < 4 % Insulation resistance 5000 M.km Dielectric strength conductor-conductor and conductor-screen (2 sec.) 2.5 kV DC Mutual capacitance < 56 nF/km Capacitance unbalance pair to ground < 1600 pF/km Nominal velocity of propagation (for information only) 0.73 c Delay skew (differential delay) 25 ns/100m Transfer impedance according IEC 61156-5 Grade 1 Coupling attenuation according IEC 61156-5 Type I High frequency (at 20) TYPE 1* 4 10 16 31.2 62.5 100 125 200 250 300 500 MHz dB/100m Attenuation 2.1 3.8 5.9 7.5 10.5 15.0 19.1 21.5 27.6 31.1 34.3 45.3 NEXT min. 75.3 66.3 60.3 57.2 52.9 48.4 45.3 43.8 40.8 39.3 38.1 34.8 dB/100m (typ.) (105) (102) (99) (96) (93) (90) (87) (84) (81) 78) (75) (72) 72.3 63.3 57.3 54.2 49.9 45.4 42.3 40.8 37.8 36.3 35.1 31.8 PS NEXT min. dB/100m (typ.) (102) (99) (96) (93) (90) (87) (84) (81) (78) (75) (72) (69) ACR dB/100m 73.2 62.5 54.4 49.8 42.4 33.4 26.2 22.3 13.2 8.3 3.9 PS ACR dB/100m 70.2 59.5 51.4 46.8 39.4 30.4 23.2 19.3 10.2 5.3 0.9 ACR-F 68.0 56.0 48.0 43.9 38.1 32.1 28.0 26.1 22.0 20.0 18.5 14.0 dB/100m PS ACR-F 65.0 53.0 45.0 40.9 35.1 29.1 25.0 23.1 19.0 17.0 15.5 11.0 dB/100m Return Loss 20.0 23.0 25.0 25.0 23.6 21.5 20.1 19.4 18.0 17.3 17.3 17.3 dB/100m dB/100m TCL level 1 40.0 34.0 30.0 28.0 25.1 22.0 20.0 19.0 17.0 16.0 EL TCTL dB/100m 35.0 23.0 15.0 10.9 5.1 Impedance 122.2 115.2 111.9 111.9 114.1 118.3 121.9 123.9 128.8 131.5 131.6 131.6 upper limit Impedance 81.8 86.8 89.4 89.4 87.7 84.5 82.0 80.7 77.6 76.0 76.0 76.0 lower limit Propagation ns/100m 570 552 545 543 540 539 538 537 536 536 536 536 delay NOTE: Limits below 4MHz are for information only. 2