Product: 7401W MachFlex, 2+1G C 20 Str BC, PVC Ins, TPE Jkt, PLTC Product Description MachFlex for High Flex, 2+1G Conductor 20AWG (19x32) Bare Copper, PVC Insulation, TPE Outer Jacket, PLTC Technical Specifications Construction Details Conductor Element Number of Element Size Stranding Material Conductor(s) 2 20 AWG 19x32 BC - Bare Copper Ground Wire 1 20 AWG 19x32 BC - Bare Copper Insulation Element Material Nom. Thickness Nom. Insulation Diameter Color Code Conductor(s) PVC - Polyvinyl Chloride 0.015 in (0.38 mm) 0.066 in (1.7 mm) Black and Numbered Ground Wire PVC - Polyvinyl Chloride 0.015 in (0.38 mm) 0.066 in (1.7 mm) Green/Yellow Outer Shield Material No Shield Outer Jacket Separator Material Nom. Thickness Nom. Diameter non-Woven Tape TPE - Thermoplastic Elastomer 0.037 in (0.94 mm) 0.221 in Overall Cable Diameter (Nominal): 0.221 in Electrical Characteristics Electricals Element Nom. Conductor DCR Max. Current Conductor(s) 10.7 Ohm/1000ft 9 Amps per Conductor at 30C Ground Wire 10.7 Ohm/1000ft (35.1 Ohm/km) 14.4 Amps per Conductor at 30C Voltage UL Voltage Rating Voltage Rating 300 V 600 V Mechanical Characteristics Temperature UL Temperature Operating UL : 90C, AWM 20327 : 105C -40C To 105C Bend Radius Stationary Min. Installation Min. 2.21 in (56.1 mm) 2.21 in Max. Pull Tension: 45 lbsBulk Cable Weight: 29 lbs/1000ft Standards and Compliance Environmental Suitability: Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance Flammability / Reaction to Fire: UL1685 UL Loading, FT2, IEEE 1202 FT4 NEC / UL Compliance: Article 725, PLTC AWM Compliance: UL AWM Style 20327, AWM I/II A/B European Directive Compliance: EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) APAC Compliance: China RoHS II (GB/T 26572-2011) History Update and Revision: Revision Number: 0.363 Revision Date: 12-20-2021 Variants Item Color Putup Type Length UPC 7401W 060250 Chrome Reel 250 ft 612825185284 7401W 0601000 Chrome Reel 1,000 ft 612825185277 7401W 0605000 Chrome Reel 5,000 ft 612825185291 2022 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.