Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 76318WS Multi-Conductor - 300V Foil/Spiral Shield, Continuous Flexing Data Applications Up to 6 Million Flex Life Cycles For more Information please call 1-800-Belden1 General Description: 22 AWG stranded (19x34) tinned copper conductors, PVC insulation, Aluminum/Polyester Foil Shield, Tinned copper spiral shield, 90% coverage, oil-resistant PVC jacket. Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material Dia. (in.) 18 22 19x34 TC - Tinned Copper 0.032 Insulation Insulation Material: Insulation Material Wall Thickness (in.) PVC - Polyvinyl Chloride 0.010 Insulation Color Code Chart: Number Color 1 Black 2 Red 3 White 4 Green 5 Orange 6 Blue 7 Brown 8 Yellow 9 Violet 10 Chrome 11 Pink 12 Tan 13 Red/Green 14 Red/Yellow 15 Red/Black 16 White/Black 17 White/Red 18 White/Green Outer Shield Outer Shield Material: Layer Type Outer Shield Material Coverage (%) 1 Tape Aluminum/Mylar 100.000 2 Serve TC - Tinned Copper 90.000 Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVC - Polyvinyl Chloride 0.040 Overall Cable Overall Nominal Diameter: 0.367 in. Mechanical Characteristics (Overall) Bulk Cable Weight: 100 lbs/1000 ft. Max. Recommended Pulling Tension: 115 lbs. Min. Bend Radius/Minor Axis: 2.900 in. Min. Bend/Installation: 2.900 in. Min. Bend Radius (Continuous Flexing): 2.900 in. Flex Cycle Rating: 6 Million Flexes Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM CEC/C(UL) Specification: CMG Page 1 of 2 10-02-2017Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 76318WS Multi-Conductor - 300V Foil/Spiral Shield, Continuous Flexing Data Applications Up to 6 Million Flex Life Cycles CEC/C(UL) Specification: CMG EU Directive 2011/65/EU (ROHS II): Yes MII Order 39 (China RoHS): Yes Customer Part Number Reference Specification: AWM/STYLE 10002, AWM/STYLE 2661, CSA AWM I/II A/B, EU Directive 2011/65/EU(RoHS2), REACH Regulation (EC 1907/2006), California Proposition 65 Flame Test CSA Flame Test: FT4 Suitability Suitability - Burial: Yes Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/ft) 0.170 Nom. Capacitance Conductor to Conductor: Freq. (MHz) Capacitance (pF/ft) 0.001 38.000 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 15.500 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/1000 ft) 2.800 Max. Operating Voltage - UL: Voltage 300V Notes (Overall) Notes: Temperature Range -10 to 105C(static), +5 to 105C (dynamic) Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc Revision Number: 0 Revision Date: 09-27-2017 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Page 2 of 2 10-02-2017