Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 77404WS Multi-Conductor - 600V Shielded, Continous Flexing Applications Up to 14 Million Flex Life Cycles For more Information please call 1-800-Belden1 General Description: 14 AWG stranded (266x38) bare copper conductors, PVC insulation, oil-resistant PVC inner jacket, tinned copper braid shield, 85% coverage, oil-resistant overall PVC jacket. Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material Dia. (in.) 3 14 266x38 BC - Bare Copper 0.080 Total Number of Conductors: 4 Ground Wire Ground Wire (Y/N): Y Ground Wire AWG: 14 Ground Wire Stranding: 266x38 Ground Wire Conductor Material: BC - Bare Copper Ground Wire Insulation Material: PVC - Polyvinyl Chloride Insulation Insulation Material: Insulation Material Wall Thickness (in.) Dia. (in.) PVC - Polyvinyl Chloride 0.022 0.124 Insulation Color Code Chart: Color Description Black Individually Numbered Yellow/Green Ground Inner Jacket Inner Jacket Material: Inner Jacket Material Nom Wall (in.) Nom. Dia. (in.) PVC - Polyvinyl Chloride 0.035 0.394 Outer Shield Outer Shield Material: Outer Shield Material Coverage (%) TC - Tinned Copper 85.000 Outer Shield Separator Material: Tissue Tape, 25& 37 Overlap, Min. Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (in.) PVC - Polyvinyl Chloride 0.050 Overall Cable Overall Nominal Diameter: 0.528 in. Mechanical Characteristics (Overall) Storage Temperature Range: -40C To +90C Installation Temperature Range: Flexing: -5C To +90C Operating Temperature Range: Flexing: -5C To +90C Bulk Cable Weight: 370 lbs/1000 ft. Max. Recommended Pulling Tension: 146 lbs. Min. Bend Radius/Minor Axis: 4.200 in. Min. Bend/Installation: 4.200 in. Min. Bend Radius (Continuous Flexing): 4.200 in. Flex Cycle Rating: 14 Million Flexes Page 1 of 2 10-02-2017Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 77404WS Multi-Conductor - 600V Shielded, Continous Flexing Applications Up to 14 Million Flex Life Cycles Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: THHN/THWN Singles AWM Specification: UL Style 2587 (600 V 90C) CSA Specification: 600 V AWM I/II A/B EU Directive 2011/65/EU (ROHS II): Yes Other Specification: AWM/STYLE 10012, AWM/STYLE 2587, AWM I/II A/B, FT1, VDE 0472, Section 803 Oil Test, EU Low Voltage Directive 2014/35/EC, EU Directive 2011/65/EU(RoHS2), REACH Regulation (EC 1907/2006), California Proposition 65 Flame Test CSA Flame Test: FT1 Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/ft) 0.170 Nom. Capacitance Cond. to Other Cond. & Ground: Description Freq. (kHz) Capacitance (pF/ft) Nom. Cond. to Cond 1.000 55.000 Nom. Ground. 1.000 99.000 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 2.500 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/1000 ft) 2.040 Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc Revision Number: 0 Revision Date: 09-27-2017 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Page 2 of 2 10-02-2017