Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 77604W Multi-Conductor - 600V Unshielded, Continous Flexing Applications Up to 14 Million Flex Life Cycles For more Information please call 1-800-Belden1 General Description: 16 AWG stranded (168x38) bare copper conductors, PVC insulation, oil-resistant overall PVC jacket. Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material Dia. (mm) 3 16 168x38 BC - Bare Copper 1.702 Total Number of Conductors: 4 Ground Wire Ground Wire (Y/N): Y Ground Wire AWG: 16 Ground Wire Stranding: 168x38 Ground Wire Conductor Material: BC - Bare Copper Ground Wire Insulation Material: PVC - Polyvinyl Chloride Insulation Insulation Material: Insulation Material Wall Thickness (mm) Dia. (mm) PVC - Polyvinyl Chloride 0.559 2.819 Insulation Color Code Chart: Color Description Red Individually Numbered Yellow/Green Ground Outer Shield Outer Shield Separator Material: Tissue Tape, 25& 37 Overlap, Min. Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.889 Overall Cable Overall Nominal Diameter: 9.195 mm Mechanical Characteristics (Overall) Storage Temperature Range: -40C To +90C Installation Temperature Range: Flexing: -5C To +90C Operating Temperature Range: Flexing: -5C To +90C Bulk Cable Weight: 318.475 Kg/Km Max. Recommended Pulling Tension: 373.649 N Min. Bend Radius/Minor Axis: 73.660 mm Min. Bend/Installation: 73.660 mm Min. Bend Radius (Continuous Flexing): 73.660 mm Flex Cycle Rating: 14 Million Flexes Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: THHN/THWN Singles AWM Specification: UL Style 2587 (600 V 90C) CSA Specification: 600 V AWM I/II A/B EU Directive 2011/65/EU (ROHS II): Yes Other Specification: AWM/STYLE 10012, AWM/STYLE 2587, AWM I/II A/B, FT1, VDE 0472, Section 803 Oil Test, EU Low Voltage Directive 2014/35/EC, EU Directive 2011/65/EU(RoHS2), REACH Regulation (EC 1907/2006), California Proposition 65 Page 1 of 2 10-02-2017Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 77604W Multi-Conductor - 600V Unshielded, Continous Flexing Applications Up to 14 Million Flex Life Cycles Flame Test CSA Flame Test: FT1 Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/m) 0.591 Nom. Capacitance Cond. to Other Cond. & Ground: Description Freq. (kHz) Capacitance (pF/m) Nom. Cond. to Cond 1.000 111.554 Nom. Conductor DC Resistance: DCR 20C (Ohm/km) 13.452 Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc Revision Number: 0 Revision Date: 09-27-2017 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Page 2 of 2 10-02-2017