Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
7851A Multi-Conductor - Enhanced Category 6 Bonded-Pair Cable
For more Information
please call
1-800-Belden1
General Description:
CAT6+ (600MHz), 4-Bonded-Pairs, U/UTP-Unshielded, Riser-CMR, Premise Horizontal Cable, 23 AWG
Solid Bare Copper Conductors, Polyolefin Insulation, Patented E-Spline, Ripcord, PVC Jacket
Usage (Overall)
Suitable Applications: Premise Horizontal Cable, Gigabit Ethernet, POE, POE+,100BaseTX, 100BaseVG ANYLAN, 155ATM,
622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy
Environments
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
4 23 Solid BC - Bare Copper
Total Number of Conductors: 8
Insulation
Insulation Material:
Insulation Material
PO - Polyolefin
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Outer Jacket Diameter:
Nom. Dia. (in.)
0.265
Outer Jacket Ripcord: Yes
Overall Cable
Overall Cabling Separator Material: Patented E-Spline Center Member
Overall Nominal Diameter: 0.227 x 0.315 in.
Pair
Pair Color Code Chart:
Number Color
1 White/Blue Stripe & Blue
2 White/Orange Stripe & Orange
3 White/Green Stripe & Green
4 White/Brown Stripe & Brown
Mechanical Characteristics (Overall)
Storage Temperature Range: -20C To +75C
Installation Temperature Range: -20C To +75C
Operating Temperature Range: 0C To +75C
Bulk Cable Weight: 35 lbs/1000 ft.
Max. Recommended Pulling Tension: 45 lbs.
Min. Bend Radius/Minor Axis: 0.500 in.
Min. Bend/Installation: 2.250 in.
Page 1 of 4 03-28-2017Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
7851A Multi-Conductor - Enhanced Category 6 Bonded-Pair Cable
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMR
NEC Articles: 800
CEC/C(UL) Specification: CMR
EU Directive 2011/65/EU (ROHS II): Yes
Other Standards: ISO/IEC 11801 ed 2.1 (2008) Class E
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Telecommunications Standards: Category 6 - TIA 568.C.2
Applicable Patents:
Country
www.belden.com/p
Flame Test
UL Flame Test: UL1666 Vertical Riser
C(UL) Flame Test: FT4
CSA Flame Test: FT4
IEEE Flame Test: 1202
Suitability
Suitability - Indoor: Yes
Suitability - Outdoor: No
Suitability - Burial: No
Sunlight Resistance: No
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 7852A
Electrical Characteristics (Overall)
Nom. Mutual Capacitance:
Capacitance (pF/ft)
15.5
Maximum Capacitance Unbalance (pF/100 m): 90
Nominal Velocity of Propagation:
VP (%)
67
Maximum Delay:
Delay (ns/100 m)
538 @ 100MHz
Max. Delay Skew:
Delay Skew (ns/100 m)
38
Maximum Conductor DC Resistance:
DCR @ 20C (Ohm/100 m)
8.2
Max. Operating Voltage - UL:
Voltage
300 V RMS
Maximum DCR Unbalanced: