Product: 7932A DataTuff 5e, 2 Bonded-Pr 24 Sol BC, PO Ins, PVC Jkt, CMR SUN RES OIL RES Product Description Industrial Ethernet Cat 5e, 2 Bonded-Pair 24AWG (Solid) Bare Copper, PO Insulation, PVC Outer Jacket, CMR SUN RES OIL RES Technical Specifications Product Overview Suitable Applications: harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. Physical Characteristics (Overall) Conductor AWG Stranding Material Nominal Diameter No. of Pairs 24 Solid BC - Bare Copper 0.02 in 2 Conductor Count: 4 Total Number of Pairs: 2 Insulation Material Nominal Diameter Nominal Wall Thickness PO - Polyolefin 0.035 in 0.009 in Bonded-Pair: Yes Color Chart Number Color 1 White/Orange Stripe & Orange 2 White/Green Stripe & Green Outer Shield Material No Shield Outer Jacket Material Nominal Diameter Ripcord PVC - Polyvinyl Chloride 0.207 in Yes Electrical Characteristics Conductor DCR Max. Conductor DCR Max. DCR Unbalance 26 Ohm/1000ft 3 % Capacitance Max. Capacitance Unbalance Nom.Mutual Capacitance 90 pF/100m 15 pF/ft Delay Max. Delay Max. Delay Skew Nominal Velocity of Propagation (VP) % 510 ns/100m 25 ns/100m 70%High Frequency Frequency Max. Insertion Loss Min. Min. Min. Min. Min. ACRF Min. PSACRF Min. RL (Return Max./Min. Input Max./Min. Fitted MHz (Attenuation) NEXT dB PSNEXT dB ACR dB PSACR dB (ELFEXT) dB (PSELFEXT) dB Loss) dB Impedance (unFitted) Impedance 1 MHz 2 dB/100m 65.3 dB 65.3 dB 63.3 dB 63.3 dB 63.8 dB 60.8 dB 20 dB 100 12 Ohm 95-110 Ohm 4 MHz 4 dB/100m 56.3 dB 56.3 dB 52.3 dB 52.3 dB 51.7 dB 48.7 dB 23.6 dB 100 12 Ohm 95-110 8 MHz 5.7 dB/100m 51.8 dB 51.8 dB 46.1 dB 46.1 dB 45.7 dB 42.7 dB 25.4 dB 100 12 Ohm 95-107 10 MHz 6.4 dB/100m 50.3 dB 50.3 dB 43.9 dB 43.9 dB 43.8 dB 40.8 dB 26 dB 100 12 Ohm 95-107 16 MHz 8.1 dB/100m 47.3 dB 47.3 dB 39.1 dB 39.1 dB 39.7 dB 36.7 dB 26 dB 100 12 Ohm 95-107 20 MHz 9.2 dB/100m 45.8 dB 45.8 dB 35.2 dB 35.2 dB 37.7 dB 34.7 dB 26 dB 100 12 Ohm 95-107 25 MHz 10.3 dB/100m 44.3 dB 44.3 dB 34.1 dB 34.1 dB 35.8 dB 32.8 dB 25.5 dB 100 15 Ohm 95-107 31.25 MHz 11.6 dB/100m 42.9 dB 42.9 dB 31.3 dB 31.3 dB 33.9 dB 30.9 dB 25 dB 100 15 Ohm 95-107 62.5 MHz 16.8 dB/100m 38.4 dB 38.4 dB 21.6 dB 21.6 dB 27.8 dB 24.8 dB 23.5 dB 100 15 Ohm 95-107 100 MHz 21.7 dB/100m 35.3 dB 35.3 dB 17.1 dB 17.1 dB 23.8 dB 20.8 dB 22.5 dB 100 15 Ohm 155 MHz 27.7 dB/100m 32.5 dB 32.5 dB 4.7 dB 4.7 dB 19.9 dB 16.9 dB 19 dB 100 18 Ohm 200 MHz 32 dB/100m 30.8 dB 30.8 dB 3 dB 3 dB 17.7 dB 14.7 dB 19 dB 100 20 Ohm 250 MHz 36.4 dB/100m 29.3 dB 29.3 dB 0 dB 0 dB 15.8 dB 12.8 dB 18 dB 100 20 Ohm 300 MHz 40.5 dB/100m 28.2 dB 28.2 dB 0 dB 0 dB 14.2 dB 11.2 dB 18 dB 100 20 Ohm 310 MHz 41.3 dB/100m 27.9 dB 27.9 dB 13.9 dB 10.9 dB 18 dB 100 20 Ohm 350 MHz 44.3 dB/100m 27.2 dB 27.2 dB 12.9 dB 9.9 dB 17 dB 100 22 Ohm Voltage UL Voltage Rating 300 V RMS Temperature Range Installation Temp Range: -25C To +75C UL Temp Rating: 60C Storage Temp Range: -40C To +85C Operating Temp Range: -40C To +75C Mechanical Characteristics Bulk Cable Weight: 18 lbs/1000ft Max. Pull Tension: 20 lbs Min. Bend Radius/Minor Axis: 0.25 in Standards NEC/(UL) Compliance: CMR, UL 444 CEC/C(UL) Compliance: CMR ISO/IEC Compliance: ISO/IEC 11801 Cat 5e CPR Euroclass: Eca Data Category: Category 5e TIA/EIA Compliance: TIA-568.C.2 Cat 5e Other Specification: EtherNet/IP Third Party Performance UL Verifieid Cat 5e Verification: Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2011/65/EU (RoHS 2): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU (RoHS 2 Yes amendment): EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes MII Order 39 (China RoHS): Yes Suitability Suitability - Oil Resistance: Yes Suitability - Outdoor: Yes