Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 7962A Multi-Conductor - Category 5e DataTuff 5 Million Flex Quad Cables For more Information please call 1-800-Belden1 General Description: 22 AWG Symmetric quad stranded tinned copper conductors, polyolefin insulation, FRPE bedding, industrial grade sunlight- and oil-resistant TPE jacket, rip cord. Sequential marking at two foot intervals. PROFINET Type C trailing cable for continuous flex applications Usage (Overall) Suitable Applications: Industrial Ethernet Cable, Harsh Environments, Category 5e, ProfiNet, 100BaseTX, CMX - Outdoor, PLTC Listed, Approved for Cable Tray Use in Class 1, Division 2, Hazardous Areas and Non-hazardous Areas, Cable Trays, Raceways, Conduit and Supported by Messenger Wires, Approved for Outdoor Usage Physical Characteristics (Overall) Conductor AWG: Conductors AWG Stranding Conductor Material Dia. (mm) 4 22 19x34 TC - Tinned Copper 0.711 Total Number of Conductors: 4 Insulation Insulation Material: Insulation Material Dia. (mm) PO - Polyolefin 1.626 Inner Jacket Inner Jacket Material: Inner Jacket Material Nom. Dia. (mm) FRPE 4.242 Outer Shield Outer Shield Material: Layer Outer Shield Trade Name Type Outer Shield Material Coverage (%) 1 Beldfoil Tape Aluminum Foil - Polyester Tape 100.000 2 Braid 85.000 Outer Jacket Outer Jacket Material: Outer Jacket Material Industrial Grade TPE - Thermo Plastic Elestomer Overall Cable Overall Nominal Diameter: 7.010 mm Pair Pair Color Code Chart: Number Color 1 White 2 Blue 3 Yellow 4 Orange Mechanical Characteristics (Overall) Storage Temperature Range: -40C To +80C Installation Temperature Range: -20C To +60C Operating Temperature Range: -40C To +80C Bulk Cable Weight: 68.457 Kg/Km Max. Recommended Pulling Tension: 244.651 N Min. Bend Radius/Minor Axis: 65.024 mm Page 1 of 3 06-09-2016Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 7962A Multi-Conductor - Category 5e DataTuff 5 Million Flex Quad Cables Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM, CMX-Outdoor, ITC, PLTC CEC/C(UL) Specification: CM AWM Specification: UL Style 20626 (600V 80C) EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes Telecommunications Standards: Category 5e - TIA 568.C.2 Other Specification: Oil Res I, Oil Res 60811-2-1, Weldspatter Resistant Flame Test UL Flame Test: UL1666 Vertical Tray C(UL) Flame Test: FT1 Suitability Suitability - Indoor: Yes Suitability - Outdoor: Yes Sunlight Resistance: Yes Oil Resistance: Yes Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Capacitance Conductor to Shield: Capacitance (pF/m) 49.215 Maximum Capacitance Unbalance (pF/100 m): 66 Nominal Velocity of Propagation: VP (%) 70 Maximum Delay: Delay (ns/100 m) 552.000 Maximum Conductor DC Resistance: DCR 20C (Ohm/100 m) 5.700 Max. Operating Voltage - UL: Voltage 300 V RMS Maximum DCR Unbalanced: DCR Unbalance 20C (%) 3 Electrical Characteristics-Premise (Overall) Premise Cable Electrical Table 1: Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. ACR (dB) Min RL (dB) 1 2.100 65.3 63.2 23.000 4 4.000 56.3 52.3 23.000 10 6.300 50.3 43.9 25.000 16 8.000 47.2 39.1 25.000 20 9.000 45.8 35.2 25.000 31.25 11.400 42.9 31.3 23.600 Page 2 of 3 06-09-2016