Product Datasheet Belden 7965ENH P/N 46013 Page 1 of 2 Cat 6 UTP FRNC non bonded Rev. 1/ 2002-11-13 Application Horizontal and building backbone cable. Support current and future Category 6 and Category 5 enhanced applications, such as: 10 Base-T, 100 Base-T, 1000 Base-T (Gigabit Ethernet), FDDI, ATM Key features and Standards nd nd General standards: ISO/IEC 11801 2 edition (2002), EN 50173 2 edition (2001), ANSI/TIA/EIA 568-b.2 (2002) Construction & Dimensions Construction: Unshielded 4 twisted pairs Pair 1 White-Blue/Blue Conductor: solid bare copper Pair 2 White-Orange/Orange Conductor diameter: AWG 23 (0,57 mm) Pair 3 White-Green/Green Conductor insulation material: Polyolefine Pair 4 White-Brown/Brown Diameter over insulation: 1,01 mm Cross web FRNC compound Colour identification according to IEC 60304 Jacket material: FRNC compound Outer diameter: 6,20 mm Electrical characteristics (at 20 C) Nominal mutual capacitance at 1 kHz 50 nF/km Maximum conductor DCR 70 Ohm/km NVP - Nominal Velocity of Propagation 0.70 c SKEW Propagation delay difference (100 MHz) typical 15 ns/100m 1) Mean Characteristic Impedance 4-100 MHz 100 5 Ohm 1) : According to cable requirements of ISO/IEC 11801 category 6, Sept. 2002. General and environmental characteristics Temperature range - operation -20C - +60C Temperature range - installation +0C - +50C Minimum bending radius - operation 25 mm Minimum bending radius - installation 50 mm Maximum pulling tension 80 N Flame retardancy IEC 332-1 Caloric value 480 kJ/m Weight (approx.) 43.9 kg/km Maximum operating voltage 48 V rms 1.4 A Maximum continuous current per conductor (25 C) Belden Wire & Cable B.V. Netherlands Tel. +31-(0)77-3878-555 - Fax. +31-(0)77-3878-488 - E-mail: sales.info belden-europe.com All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. All printing errors are subject to correction. Technical specifications are subject to change without notice.Product Datasheet Belden 7965ENH P/N 46013 Page 2 of 2 Cat 6 UTP FRNC non bonded Rev. 1/ 2002-11-13 Electrical characteristics (at 20 C) Attenuation Frequency 1 4 10 16 20 31.2 62.5 100 155 200 250 MHz 1) Spec. (Max.) - 4.0 6.0 7.6 8.5 10.8 15.5 19.9 25.3 29.2 33 dB/ 100m Typical 1.7 3.5 5.6 7.1 8.0 10.1 14.4 18.6 23.6 27.0 30.7 dB/ 100m NEXT (Near end crosstalk) Frequency 1 4 10 16 20 31.2 62.5 100 155 200 250 MHz 1) Spec. (Min.) - 66 60 57 56 53 48 45 42 41 39 dB/ 100m Typical 76 73 66 64 63 56 55 52 49 48 45 dB/ 100m Power sum NEXT Frequency 1 4 10 16 20 31.2 62.5 100 155 200 250 MHz 1) Spec. (Min.) - 63 57 54 53 50 45 42 39 38 36 dB/ 100m Typical 74 71 64 62 61 54 53 50 47 46 43 dB/ 100m Power sum ELFEXT Frequency 1 4 10 16 20 31.2 62.5 100 155 200 250 MHz 1) Spec. (Min.) - 53 45 41 39 35 29 25 21 19 17 dB/ 100m Typical 70 64 57 51 49 45 39 35 31 29 27 dB/ 100m ACR Frequency 1 4 10 16 20 31.2 62.5 100 155 200 250 MHz 1) Spec. (Min.) - 62.0 54.0 49.4 47.5 42.2 32.5 25.1 16.7 11.8 6.0 dB/ 100m Typical 74 70 60 57 55 46 41 33 25 21 14 dB/ 100m Power sum ACR Frequency 1 4 10 16 20 31.2 62.5 100 155 200 250 MHz 1) Spec. (Min.) - 59.0 51.0 46.4 44.5 39.2 29.5 22.1 13.7 8.8 3.0 dB/ 100m Typical 72 68 58 55 53 44 39 31 23 19 12 dB/ 100m Return Loss Frequency 1 4 10 16 20 31.2 62.5 100 155 200 250 MHz 1) Spec. (Min.) - 23.0 25.0 25.0 25.0 23.6 21.5 20.1 18.8 18.0 17.3 dB/ 100m Typical 33 36 44 42 40 38 36 31 27 25 24 dB/ 100m 1) : Specification values according to cable requirements of ISO/IEC 11801 category 6, Sept. 2002. Note: Values between brackets are for information only Ordering information MARKING Text on the cable jacket Inkjet printing BELDEN 7965ENH UTP CAT6 4PR AWG23 LSNH ISO/IEC 11801 EN50173 VERIFIED 100 OHM Meter marking: Yes JACKET COLOUR Colour RAL code Blue RAL 5015 PACKAGING (PUT UP) 500m and 1000m Crate reels Belden Wire & Cable B.V. Netherlands Tel. +31-(0)77-3878-555 - Fax. +31-(0)77-3878-488 - E-mail: sales.info belden-europe.com All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. All printing errors are subject to correction. Technical specifications are subject to change without notice.