Product: 8233P Triax, RG11, 14 AWG Solid BC, Double BC Braids, PVDF Jkt, CMP Product Description Triax, RG11, 14 AWG Solid Bare Copper Conductor, FEP Insulation, 95% Bare Copper Braid Shield, PVDF Insulation 80% Bare Copper Braid Shield, PVDF Jacket, CMP Technical Specifications Product Overview Suitable Applications: Analog Video Interconnect camera to CCU (camera control unit) Construction Details RG Type: 11 Conductor AWG Stranding Nom. Diameter Material 14 Solid 0.064 in BC - Bare Copper Insulation Material Nom. Diameter FEP - Fluorinated Ethylene Propylene (Foam) 0.285 in Inner Shield Material Layer Inner Shield Type Material Coverage 1 Braid Bare Copper (BC) 95% Inner Jacket Material Material Nom. Diameter PVDF - Polyvinylidene Fluoride 0.350 in Outer Shield Material Layer Outer Shield Type Material Coverage 1 Braid Bare Copper (BC) 80% Outer Jacket Material Material Nom. Diameter PVDF - Polyvinylidene Fluoride 0.408 in Electrical Characteristics Return Loss (RL) Frequency MHz Min. Return Loss dB 5 - 850 MHz 21 dB 850 - 4500 MHz 15 dB Attenuation Frequency Nom. Attenuation dB/100ft 1 MHz 0.09 dB/100ft 3.6 MHz 0.28 dB/100ft10 MHz 0.47 dB/100ft 71.5 MHz 1.33 dB/100ft 135 MHz 1.90 dB/100ft 270 MHz 2.94 dB/100ft 360 MHz 3.42 dB/100ft 540 MHz 4.46 dB/100ft 720 MHz 5.41 dB/100ft 750 MHz 5.51 dB/100ft 1000 MHz 6.74 dB/100ft 1500 MHz 9.03 dB/100ft 2000 MHz 11.30 dB/100ft 2250 MHz 12.54 dB/100ft 3000 MHz 17.00 dB/100ft 4000 MHz 27.45 dB/100ft Electricals Nom. Conductor DCR Nom. Inner Shield DCR Nom. Outer Shield DCR Nom. Capacitance Cond-to-Shield Nom. Impedence 2.5 Ohm/1000ft 1.6 Ohm/1000ft 1.4 Ohm/1000ft 16.5 pF/ft 75 Ohm Voltage UL Voltage Rating 300 V (CMP) Mechanical Characteristics Temperature UL Rating Operating 125C -15C to +125C Bend Radius Installation Min. 4.0 in Bulk Cable Weight: 128 lbs/1000ft Max. Pull Tension: 194 lbs Standards and Compliance Environmental Suitability: Indoor - Plenum, Indoor Sustainability: CA Prop 65 Flammability / Fire Resistance: NFPA 262, NFPA 262, FT6 NEC / UL Compliance: CMP CEC / C(UL) Compliance: CMP European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE) APAC Compliance: China RoHS II (GB/T 26572-2011) Non-Plenum Number: 8233A History Update and Revision: Revision Number: 0.310 Revision Date: 08-25-2020 2020 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on anASI basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden s standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden s knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.