Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 82907 Coax - 50 Ohm Ethernet Coax For more Information please call 1-800-Belden1 General Description: Thinnet 10Base2, 20 AWG stranded (19x32) .037 tinned copper conductor, plenum Ethernet, FPFA insulation, Duobond II + overall TC braid shield (93% coverage), Flamarrest jacket. Usage (Overall) Suitable Applications: Thin Ethernet Physical Characteristics (Overall) Conductor AWG: Coax AWG Stranding Conductor Material Dia. (in.) 1 20 19x32 TC - Tinned Copper .037 Total Number of Conductors: 1 Insulation Insulation Material: Insulation Material Dia. (in.) FPFA - Foam Perflouoroalkoxy .095 Outer Shield Outer Shield Material: Layer Outer Shield Trade Name Type Outer Shield Material Coverage (%) 1 Bonded Duofoil Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100 2 Braid TC - Tinned Copper 93 Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Flamarrest LS PVC - Low Smoke Polyvinyl Chloride Overall Cable Overall Nominal Diameter: 0.160 in. Mechanical Characteristics (Overall) Operating Temperature Range: 0C To +75C UL Temperature Rating: 75C Bulk Cable Weight: 22 lbs/1000 ft. Max. Recommended Pulling Tension: 45 lbs. Min. Bend Radius/Minor Axis: 1.750 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CL2P, CMP CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes IEEE Specification: IEEE802.3 10Base2 EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2006 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes Page 1 of 3 04-18-2017Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 82907 Coax - 50 Ohm Ethernet Coax CA Prop 65 (CJ for Wire & Cable): Yes MII Order 39 (China RoHS): Yes RG Type: 58A/U Flame Test UL Flame Test: NFPA 262 CSA Flame Test: FT6 Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 9907 Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) Tolerance (Ohms) 50 +/- 2 Nom. Inductance: Inductance (H/ft) .0635 Nom. Capacitance Conductor to Shield: Capacitance (pF/ft) 25.4 Nominal Velocity of Propagation: VP (%) 80 Nominal Delay: Delay (ns/ft) 1.27 Nom. Conductor DC Resistance: DCR 20C (Ohm/1000 ft) 8.8 Maximum Loop Resistance: Resistance (Ohm/1000 ft) 15.24 Nominal Outer Shield DC Resistance: DCR 20C (Ohm/1000 ft) 5.8 Nom. Attenuation: Freq. (MHz) Attenuation (dB/100 ft.) 1 .43 10 1.3 50 2.91 100 4.18 200 6.1 400 9.2 700 12.9 900 15.0 1000 16.0 Max. Operating Voltage - UL: Voltage 300 V RMS Put Ups and Colors: Item Putup Ship Weight Color Notes Item Desc 82907 877U1000 1,000 FT 23.000 LB NATURAL O 20 FPFA BRD FLMRST 82907 8771000 1,000 FT 23.000 LB NATURAL C Z 20 FPFA BRD FLMRST 82907 8772500 2,500 FT 57.500 LB NATURAL C Z 20 FPFA BRD FLMRST 82907 877500 500 FT 12.500 LB NATURAL C Z 20 FPFA BRD FLMRST Notes: C = CRATE REEL PUT-UP. O = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR UNREEL CARTONS FROM LENGTH SHOWN. Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. Page 2 of 3 04-18-2017