Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8412 Multi-Conductor - Two-Conductor, Low-Impedance Cable
For more Information
please call
1-800-Belden1
General Description:
20 AWG stranded (7x28) high-conductivity TC conductors, FEP Teflon insulation, TC braid shield (85%
coverage), FEP Teflon jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material Dia. (in.)
2 20 26x34 High Conductivity TC - Tinned Copper .037
Total Number of Conductors: 2
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
EPDM - Ethylene Propylene Diene Monomer Rubber 0.023
Outer Shield
Outer Shield Material:
Layer # Type Outer Shield Material Coverage (%)
1 Braid Cotton
2 Braid TC - Tinned Copper 85
Outer Shield Separator Material: Cotton Wrap
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
EPDM - Ethylene Propylene Diene Monomer Rubber
Overall Cable
Overall Cabling Color Code Chart:
Number Color
1 White
2 Black
Overall Cabling Separator Material: Rayon Braid
Overall Nominal Diameter: 0.262 in.
Mechanical Characteristics (Overall)
Operating Temperature Range: -50C To +90C
Non-UL Temperature Rating: 90C
Bulk Cable Weight: 44 lbs/1000 ft.
Max. Recommended Pulling Tension: 100 lbs.
Min. Bend Radius/Minor Axis: 2.750 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
Page 1 of 2 05-22-2017Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8412 Multi-Conductor - Two-Conductor, Low-Impedance Cable
MII Order #39 (China RoHS): Yes
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
67.000
Nom. Inductance:
Inductance (H/ft)
.18
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
33.000
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
58.000
Nom. Conductor DC Resistance:
DCR @ 20C (Ohm/1000 ft)
10.600
Nominal Outer Shield DC Resistance:
DCR @ 20C (Ohm/1000 ft)
4.500
Max. Operating Voltage - Non-UL:
Voltage
600 V RMS
Max. Recommended Current:
Current
4 Amps per conductor @ 25C
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
8412 0021000 1,000 FT 47.000 LB RED C 2 #20 EPDM BRD EPDM
8412 0041000 1,000 FT 47.000 LB YELLOW C 2 #20 EPDM BRD EPDM
8412 0061000 1,000 FT 47.000 LB BLUE, LIGHT C 2 #20 EPDM BRD EPDM
8412 010U1000 1,000 FT 46.000 LB BLACK 2 #20 EPDM SHLD EPDM
8412 010U500 500 FT 23.500 LB BLACK 2 #20 EPDM SHLD EPDM
8412 010100 100 FT 5.200 LB BLACK 2 #20 EPDM BRD EPDM
8412 0101000 1,000 FT 47.000 LB BLACK C 2 #20 EPDM BRD EPDM
8412 010250 250 FT 12.000 LB BLACK 2 #20 EPDM BRD EPDM
8412 010500 500 FT 24.000 LB BLACK C 2 #20 EPDM BRD EPDM
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 0 Revision Date: 05-19-2017
2017 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on anAS I basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributors inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Beldens knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU).
Page 2 of 2 05-22-2017