Product: 84303 50 Ohm Coax, RG303, 19 AWG Solid SCCCS, SCC Braid, FEP Jacket, CL2P Product Description RG-303/U, 19 AWG solid .037 silver-coated copper-covered steel conductor, plenum, TFE insulation, silver-coated copper braid shield (95% coverage), FEP jacket, commercial non-QPL product. Technical Specifications Physical Characteristics (Overall) Conductor AWG Stranding Material Nominal Diameter No. of Coax 19 Solid SCCS - Silvered Copper Covered Steel 0.037 in 1 Conductor Count: 1 Insulation Material Material Trade Name Nominal Diameter PTFE - Polytetrafluoroethylene Teflon 0.116 in Outer Shield Type Layer Material Coverage % Braid 1 Silvered Copper (SC) 95% Outer Jacket Material Nominal Diameter FEP - Fluorinated Ethylene Propylene 0.17 in Electrical Characteristics Conductor DCR Nominal Conductor DCR Nominal Conductor DCR Conductor Resistance Nominal Outer Shield DCR Outer Conductor DCR 16.3 Ohm/1000ft 16.3 Ohm/1000ft 4.3 Ohm/1000ft 4.3 Ohm/1000ft Capacitance Nom. Capacitance Conductor to Shield 29 pF/ft Inductance Nominal Inductance 0.067 H/ft Impedance Nominal Characteristic Impedance 50 Ohm High Frequency (Nominal/Typical) Frequency MHz Nom. Insertion Loss 1 MHz 0.3 dB/100ft 10 MHz 1.1 dB/100ft50 MHz 2.7 dB/100ft 100 MHz 3.9 dB/100ft 200 MHz 5.6 dB/100ft 400 MHz 8.2 dB/100ft 700 MHz 11 dB/100ft 900 MHz 12.5 dB/100ft 1000 MHz 13.5 dB/100ft Delay Nominal Delay Nominal Velocity of Propagation (VP) % 1.46 ns/ft 70% High Frequency Frequency MHz Max. Insertion Loss (Attenuation) 50 MHz 2.7 dB/100ft 400 MHz 8.6 dB/100ft 1000 MHz 15 dB/100ft 3000 MHz 28 dB/100ft Voltage Description UL Voltage Rating Voltage Rating V MIL 150 V RMS 1400 V RMS (Mil Spec) VSWR Frequency MHz Max. VSWR 50 MHz - 1000 MHz per M17/111-RG303 Temperature Range UL Temp Rating: 200C Operating Temp Range: -70C To +200C Mechanical Characteristics Bulk Cable Weight: 30 lbs/1000ft Max. Pull Tension: 112 lbs Min. Bend Radius/Minor Axis: 2 in Standards NEC/(UL) Compliance: CL2P RG Type: 303 Military Compliance: Commercial, non-QPL product (M17/111-RG303) Qualified Products List (QPL): No Applicable Environmental and Other Programs Environmental Space: Outdoor - Aerial EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2011/65/EU (RoHS 2): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU (RoHS 2 amendment): Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: No MII Order 39 (China RoHS): Yes Suitability Suitability - Aerial: Yes - When supported by messenger wire Suitability - Burial: No Suitability - Hazardous Locations: No Suitability - Indoor: Yes Suitability - Outdoor: Yes Suitability - Sunlight Resistance: No